Wilden A2 B Original Plastic Скачать руководство пользователя страница 11

9

WILDEN PUMP & ENGINEERING, LLC

WIL-10070-E-03

SECTION 7A

INSTALLATION

All Wilden pumps are manufactured with a variety of materi-
als for the air distribution system, liquid path and elastomers.  
This variety is offered to satisfy the temperature, chemical 
compatibility, abrasion and flex life requirements for most 
applications.  Consult manual for available materials and 
temperature limitations for this pump model.

For Accu-Flo™ models only, all wiring used to operate the 
pump should be placed and connected according to all 
applicable electrical codes.  It is important that the wiring 
be of adequate gauge to carry the current required to oper-
ate the pump.  In addition, it is necessary that the electrical 
power supply be large enough to supply the current required 
to operate the pump.  Wiring should be above ground level if 
possible (in case of fluid spill or leakage), and all wiring and 
connections which could become wet or damp should be 
made watertight.

The suction pipe used for installation should be sized equal 
to, or greater than, the pump liquid inlet connection.  This 
will minimize pump cavitation and potential blockages of the 
pump inlet.  The discharge piping should also be sized equal 
to, or greater than, the pump liquid discharge connection. 

 

If the pump is to be used in a self-priming application, be 
sure that all connections are airtight and that the suction lift 
is within the pump’s ability. (Consult manual for suction lift 
information.)  Note: Materials of construction and elastomer 
materials have an effect on suction lift parameters.  

INSTALLATION: Months of careful planning, study and selec-
tion efforts can result in unsatisfactory pump performance if 
installation details are left to chance.

Premature failure and long term dissatisfaction can be 
avoided if reasonable care is exercised throughout the instal-
lation process.

LOCATION:  Noise, safety, and other logistical factors 
usually dictate that “utility” equipment be situated away from 
the production floor.  Multiple installations with conflicting 
requirements can result in congested utility areas, leaving few 
choices for siting additional pumps.

Within the framework of these and other existing conditions, 
every pump should be located in such a way that four key 
factors are balanced against each other to maximum advan-
tage.

1. ACCESS:  First of all, the location should be accessible.  
If it is easy to reach the pump, maintenance personnel will 
have an easier time carrying out routine inspections and 
adjustments.  Should major repairs become necessary, ease 
of access can play a key role in speeding the repair process 
and reducing total downtime.

2. AIR SUPPLY:  Every pump location should have an air 
line large enough to supply the volume of air necessary to 
achieve the desired pumping rate. (Consult manual for perfor-
mance information.)  The use of an air filter before the pump 
will ensure that the majority of pipeline contaminants will be 

eliminated.  For best results, the pump should use an air filter, 
regulator system.

Sound levels are reduced below OSHA specifications using 
the standard Wilden muffler.

3. ELEVATION:  Selecting a site that is well within the pump’s 
dynamic lift capability will assure that a loss-of-prime condi-
tion will be avoided.  In addition, pump efficiency can be 
adversely effected if proper attention is not given to site 
location.

4. PIPING:  Final determination of the pump site should not 
be made until the piping problems of each possible location 
have been evaluated.  The impact of current and future instal-
lations should be considered ahead of time to make sure that 
inadvertent restrictions are not created for any remaining 
sites.

The best choice possible will be a site involving the shortest 
and straightest hook-up of suction and discharge piping. 

 

Unnecessary elbows, bends, and fittings should be avoided.  
Pipe sizes should be selected so as to keep friction losses 
within practical limits.  All piping should be supported inde-
pendently of the pump to avoid damage.  In addition, the 
piping should be aligned so as to avoid placing stress on the 
pump fittings. 

Flexible hose can be installed to aid in absorbing the forces 
created by the natural reciprocating action of the pump.  If 
the pump is to be bolted down to a solid location, a mounting 
pad placed between the pump and the foundation will assist 
in minimizing pump vibration.  Flexible connections between 
the pump and rigid piping will also assist in minimizing pump 
vibration.  If quick-closing valves are installed at any point 
in the discharge system, or if pulsation within a system 
becomes a problem, a Wilden Equalizer surge dampener 
should be installed to protect the pump, piping and gauges 
from surges and water hammer.  Installation of a tee at the 
discharge of the pump will allow the addition of an Equalizer 
to the system at a later date without requiring piping modifi-
cations. Installation of inlet and discharge isolation valves are 
also recommended to make service and repair easier.

Pumps in service with a positive suction head are most effi-
cient when pressure is limited to 0.4 - 0.7 bar (7-10 psig).  
Premature diaphragm failure may occur if positive suction 
exceeds these recommended pressures.  

A STRAINER SHOULD BE USED ON THE SUCTION LINE 
OF THE SYSTEM IF THERE IS A POSSIBILITY THAT 
SOLIDS ENTERING THE PUMP MAY EXCEED THE 
PUMP’S SOLIDS HANDLING CAPABILITIES.

PLEASE READ AND FOLLOW ALL CAUTIONS NOTED IN  
THIS MANUAL.

Pump should be thoroughly flushed before installing into 
process line.

Blow out air line for 10 to 20 seconds before attaching 
pump to clear all pipe line debris.

Содержание A2 B Original Plastic

Страница 1: ...EOM S i m p l i f y y o u r p r o c e s s Engine e ri n g Opera ti o n Maint e n a n ce Original Series PLASTIC Pumps A2 WIL 10070 E 03 REPLACES WIL 10070 E 02...

Страница 2: ...TION 6 70 30 OPERATING CONDITION A A2T PLASTIC Rubber Fitted T Series Center Section 8 A A2T PLASTIC PTFE Fitted T Series Center Section 8 B A2P PLASTIC Rubber Fitted P Series Center Section 8 B A2P P...

Страница 3: ...ly pressure CAUTION Plastic series pumps are made of virgin plastic and are not UV stabilized Direct sunlight for prolonged periods can cause deterioration of plastics CAUTION Before any maintenance o...

Страница 4: ...l SS outer pistons DIN flange 0458 A2 Plastic Accu Flo 24V DC coil Wil Gard II 220V DIN flange 0567 Split manifold Accu Flo 24V DC coil 0570 Split manifold Accu Flo 24V AC 12V DC coil 0509 adapter blo...

Страница 5: ...let valve ball and fill the liquid chamber see shaded area FIGURE 2 When the solenoid valve is deenergized the air valve redirects pres surized air to the back side of diaphragm B The pressurized air...

Страница 6: ...F H G J H J M K L R N P B C D E F G M 25 mm 1 ANSI DIN FLANGE LIQUID INLET 25 mm 1 ANSI DIN FLANGE LIQUID DISCHARGE FLANGE 150 pound class DIMENSIONS ITEM METRIC mm STANDARD inch A 297 11 7 B 74 2 9 C...

Страница 7: ...INLET 25 mm 1 ANSI DIN FLANGE LIQUID DISCHARGE 25 mm 1 ANSI DIN FLANGE LIQUID INLET 25 mm 1 ANSI DIN FLANGE LIQUID DISCHARGE DIMENSIONS ITEM METRIC mm STANDARD inch A 297 11 7 B 74 2 9 C 147 5 8 D 307...

Страница 8: ...pumps should be specified so that daily operation parameters will fall in the center of the pump performance curve Nm3 h LPM Height 335 mm 13 2 Width 297 mm 11 7 Depth 239 mm 9 4 Est Ship Weight Polyp...

Страница 9: ...umps should be specified so that daily operation parameters will fall in the center of the pump performance curve Nm3 h LPM SECTION 5D PERFORMANCE CURVES A2P PLASTIC PTFE FITTED Height 356 mm 14 0 Wid...

Страница 10: ...odified under static air and fluid pressure condition This curve can be applied to different pressure conditions to estimate the change in flow due to stroke rate 0 7ATER ISCHARGE LOW 2ATE These curve...

Страница 11: ...rge enough to supply the volume of air necessary to achieve the desired pumping rate Consult manual for perfor mance information The use of an air filter before the pump will ensure that the majority...

Страница 12: ...essure viscosity and abrasiveness of process fluid all effect the parts life of a Wilden pump Periodic inspections have been found to offer the best means for preventing unscheduled pump downtime Pers...

Страница 13: ...ck for sticking ball check valves If the material being pumped is not compatible with the pump elastomers swelling may occur Replace ball check valves and o ring with the proper elastomers 5 Check to...

Страница 14: ...comes in both PVDF and polypropylene The single piece center section consisting of center block and air chambers is molded of polypropylene All o rings used in the pump are of a special material and s...

Страница 15: ...p bands that secure the liquid cham bers to the center section Step 9 Figure 9 Rotate the clamp bands so that they can be removed Step 4 Figure 4 Remove the top liquid retainer to expose the valve bal...

Страница 16: ...mbly from center section assembly Step 13 Figure 13 To remove the remaining diaphragm assembly from the shaft secure shaft with soft jaws a vise fitted with plywood or other suitable material to ensur...

Страница 17: ...ean the inside of the center section shaft bushing to ensure no damage is done to new seals Stainless bolts should be lubed to reduce the possibility of seizing during tightening Be sure to tighten ou...

Страница 18: ...16 WILDEN PUMP ENGINEERING LLC WIL 10070 E 03 Adapter Block Version SECTION 9A EXPLODED VIEW PARTS LISTING A2T PLASTIC ACCU FLO PTFE Assembly...

Страница 19: ...hragm 2 N R N R 02 1060 51 02 1060 51 27 Tee Section O Ring 4 02 1300 60 400 02 1300 60 400 28 Clamp Band Assembly 2 02 7300 03 400 02 7300 03 400 02 7300 03 400 02 7300 03 400 29 Clamp Band Bolt 5 16...

Страница 20: ...18 WILDEN PUMP ENGINEERING LLC WIL 10070 E 03 SECTION 9B EXPLODED VIEW PARTS LISTING A2P PLASTIC ACCU FLO Standard Assembly Adapter Block Version PTFE Assembly...

Страница 21: ...2 5160 21 400 02 5160 20 400 02 5160 21 400 24 Top Retainer 2 02 5411 20 400 02 5411 21 400 02 5411 20 400 02 5411 21 400 25 Bottom Retainer 2 02 5420 20 400 02 5420 21 400 02 5420 20 400 02 5420 21 4...

Страница 22: ...1010 56 02 1080 56 N A N A N A N A Wil Flex Orange 02 1010 58 02 1080 58 02 1200 58 400 02 1300 58 400 02 1220 58 02 1230 58 Neoprene Backup Black 02 1060 511 N A N A N A N A N A 1 Saniflex back up di...

Страница 23: ...omes first Failure due to normal wear misapplication or abuse is of course excluded from this warranty Since the use of Wilden pumps and parts is beyond our control we cannot guarantee the suitability...