SECTION 7D – ACCU-FLO™

TROUBLESHOOTING

Pump will not run.
1.  Check for pressurized air at the inlet.
2.  Check air inlet and filter for debris.
3.  Connect a test lamp to the two wires which run to pump 

and ensure that the lamp cycles on and off.

4.  Make sure that the air valve manual override (small red 

knob on front of valve) is switched to the “0” position.

5.  Check pilot pressure vent at the top of the operator/coil 

assembly to ensure that it is not clogged.

6.  Check for a worn out air valve. If air continually blows out 

the exhaust in very large quantities, the air valve seals 
may be worn beyond their ability to function. In this case, 
the valve must be replaced.

NOTE: Before the valve is scrapped, it is possible that it may 
be saved by completely disassembling the valve, cleaning all 
components and relubricating the valve.

Pump runs but little or no fluid comes out.
1.  Check that the discharge isolation valve is not closed.
2.  Check that the electronic signal is slow enough that the 

pump is able to complete each physical stroke before 
it is signaled to change direction. The time required to 
complete the stroke is determined by a variety of factors 
which include fluid viscosity and head pressure.

3.  Check for pump cavitation; slow pump speed down to 

match the thickness of the material being pumped.

4.  Check for sticking ball check valves. If the material being 

pumped is not compatible with the pump elastomers, 
swelling may occur. Replace ball check valves and o-ring 
with the proper elastomers.

5.  Check to make sure that all suction connections are air 

tight, and that the clamp bands are properly tightened.

Pump air passages blocked with ice.
1.  Check for excessive moisture in compressed air line. As 

the air expands out the exhaust during the operation of 
the pump, water vapor entrapped in the compressed air 

can freeze and block the air passageways in the pump. 
If this occurs, it may be necessary to install a coalesc-
ing filter, an air dryer, or a hot air generator for the 
compressed air.

Air bubbles in pump discharge.
1.  Check for ruptured diaphragm.
2.  Check tightness of clamp bands, and the integrity of the

o-rings, especially at intake manifold.

Product comes out air exhaust.
1.  Check for diaphragm rupture.
2.  Check tightness of piston plates to shaft.

Pump rattles.
1.  See E9 Troubleshooting Guide.
2.  Create false discharge head or suction lift.

Solenoid buzzes or solenoid burnout.
1.  Incorrect voltage, faulty or dirty solenoid.

Solenoid valve fails to shift electrically but shifts with 
manual override.
1.  Incorrect voltage, defective coil or wiring.

Solenoid valve fails to shift electrically or with manual 
override.

1.  Inadequate air supply, contamination, inadequate or 

improper lubrication, mechanical binding in the valve.

Valve shifts but fails to return.

1.  Broken spring, mechanical binding.

Excessive leaking from air valve vent.

1.  Worn seals in air valve.

Содержание A2 B Original Plastic

Страница 1: ...EOM S i m p l i f y y o u r p r o c e s s Engine e ri n g Opera ti o n Maint e n a n ce Original Series PLASTIC Pumps A2 WIL 10070 E 03 REPLACES WIL 10070 E 02...

Страница 2: ...TION 6 70 30 OPERATING CONDITION A A2T PLASTIC Rubber Fitted T Series Center Section 8 A A2T PLASTIC PTFE Fitted T Series Center Section 8 B A2P PLASTIC Rubber Fitted P Series Center Section 8 B A2P P...

Страница 3: ...ly pressure CAUTION Plastic series pumps are made of virgin plastic and are not UV stabilized Direct sunlight for prolonged periods can cause deterioration of plastics CAUTION Before any maintenance o...

Страница 4: ...l SS outer pistons DIN flange 0458 A2 Plastic Accu Flo 24V DC coil Wil Gard II 220V DIN flange 0567 Split manifold Accu Flo 24V DC coil 0570 Split manifold Accu Flo 24V AC 12V DC coil 0509 adapter blo...

Страница 5: ...let valve ball and fill the liquid chamber see shaded area FIGURE 2 When the solenoid valve is deenergized the air valve redirects pres surized air to the back side of diaphragm B The pressurized air...

Страница 6: ...F H G J H J M K L R N P B C D E F G M 25 mm 1 ANSI DIN FLANGE LIQUID INLET 25 mm 1 ANSI DIN FLANGE LIQUID DISCHARGE FLANGE 150 pound class DIMENSIONS ITEM METRIC mm STANDARD inch A 297 11 7 B 74 2 9 C...

Страница 7: ...INLET 25 mm 1 ANSI DIN FLANGE LIQUID DISCHARGE 25 mm 1 ANSI DIN FLANGE LIQUID INLET 25 mm 1 ANSI DIN FLANGE LIQUID DISCHARGE DIMENSIONS ITEM METRIC mm STANDARD inch A 297 11 7 B 74 2 9 C 147 5 8 D 307...

Страница 8: ...pumps should be specified so that daily operation parameters will fall in the center of the pump performance curve Nm3 h LPM Height 335 mm 13 2 Width 297 mm 11 7 Depth 239 mm 9 4 Est Ship Weight Polyp...

Страница 9: ...umps should be specified so that daily operation parameters will fall in the center of the pump performance curve Nm3 h LPM SECTION 5D PERFORMANCE CURVES A2P PLASTIC PTFE FITTED Height 356 mm 14 0 Wid...

Страница 10: ...odified under static air and fluid pressure condition This curve can be applied to different pressure conditions to estimate the change in flow due to stroke rate 0 7ATER ISCHARGE LOW 2ATE These curve...

Страница 11: ...rge enough to supply the volume of air necessary to achieve the desired pumping rate Consult manual for perfor mance information The use of an air filter before the pump will ensure that the majority...

Страница 12: ...essure viscosity and abrasiveness of process fluid all effect the parts life of a Wilden pump Periodic inspections have been found to offer the best means for preventing unscheduled pump downtime Pers...

Страница 13: ...ck for sticking ball check valves If the material being pumped is not compatible with the pump elastomers swelling may occur Replace ball check valves and o ring with the proper elastomers 5 Check to...

Страница 14: ...comes in both PVDF and polypropylene The single piece center section consisting of center block and air chambers is molded of polypropylene All o rings used in the pump are of a special material and s...

Страница 15: ...p bands that secure the liquid cham bers to the center section Step 9 Figure 9 Rotate the clamp bands so that they can be removed Step 4 Figure 4 Remove the top liquid retainer to expose the valve bal...

Страница 16: ...mbly from center section assembly Step 13 Figure 13 To remove the remaining diaphragm assembly from the shaft secure shaft with soft jaws a vise fitted with plywood or other suitable material to ensur...

Страница 17: ...ean the inside of the center section shaft bushing to ensure no damage is done to new seals Stainless bolts should be lubed to reduce the possibility of seizing during tightening Be sure to tighten ou...

Страница 18: ...16 WILDEN PUMP ENGINEERING LLC WIL 10070 E 03 Adapter Block Version SECTION 9A EXPLODED VIEW PARTS LISTING A2T PLASTIC ACCU FLO PTFE Assembly...

Страница 19: ...hragm 2 N R N R 02 1060 51 02 1060 51 27 Tee Section O Ring 4 02 1300 60 400 02 1300 60 400 28 Clamp Band Assembly 2 02 7300 03 400 02 7300 03 400 02 7300 03 400 02 7300 03 400 29 Clamp Band Bolt 5 16...

Страница 20: ...18 WILDEN PUMP ENGINEERING LLC WIL 10070 E 03 SECTION 9B EXPLODED VIEW PARTS LISTING A2P PLASTIC ACCU FLO Standard Assembly Adapter Block Version PTFE Assembly...

Страница 21: ...2 5160 21 400 02 5160 20 400 02 5160 21 400 24 Top Retainer 2 02 5411 20 400 02 5411 21 400 02 5411 20 400 02 5411 21 400 25 Bottom Retainer 2 02 5420 20 400 02 5420 21 400 02 5420 20 400 02 5420 21 4...

Страница 22: ...1010 56 02 1080 56 N A N A N A N A Wil Flex Orange 02 1010 58 02 1080 58 02 1200 58 400 02 1300 58 400 02 1220 58 02 1230 58 Neoprene Backup Black 02 1060 511 N A N A N A N A N A 1 Saniflex back up di...

Страница 23: ...omes first Failure due to normal wear misapplication or abuse is of course excluded from this warranty Since the use of Wilden pumps and parts is beyond our control we cannot guarantee the suitability...

Отзывы: