WIKA operating instructions thermowell, model TW61
11593963.06 04/2019 EN/DE/FR/ES
9
EN
2. Design and function
DIN 11866 row B or ISO pipes
DIN 11866 row A or metric
3) Maximum operating temperature 150 °C
4) All thermowells of this series that are internally pressurised, with a nominal diameter (DN) > 25 mm, are
manufactured and tested to module H of the pressure equipment directive.
Nominal
width of
pipe
Nominal
pressure
in bar
Outer
diameter
of pipe
Pipe
schedule
Pipe
length
Thermowell
insertion
length
Neck tube
length
TR21-B TR22-B
DN (OD)
PN
3) 4)
Ø D
s
TL L
1
U
1
M
M
8 (13.5)
25
13.5
1.6
32
55
14
43
121
10 (17.2)
25
17.2
1.6
34
55
16
41
119
15 (21.3)
25
21.3
1.6
36
58
18
39
117
20 (26.9)
25
26.9
1.6
55
81
30
27
105
25 (33.7)
25
33.7
2.0
60
91
30
27
105
32 (42.4)
25
42.4
2.0
65
102 30
27
105
40 (48.3)
25
48.3
2.0
65
108 30
27
105
50 (60.3)
25
60.3
2.0
90
145 45
12
90
65 (76.1)
16
76.1
2.0
110 173 45
12
90
80 (88.9)
16
88.9
2.3
130 203 45
12
90
Nominal
width of
pipe
Nominal
pressure
in bar
Outer
diameter
of pipe
Pipe
schedule
Pipe
length
Thermowell
insertion
length
Neck tube
length
TR21-B TR22-B
OD
PN
3) 4)
Ø D
s
TL L
1
U
1
M
M
10
25
13
1.5
35
55
14
43
121
15
25
19
1.5
35
55
18
39
117
20
25
23
1.5
40
63
18
39
117
25
25
29
1.5
50
77
30
27
105
32
25
35
1.5
55
87
30
27
105
40
25
41
1.5
60
97
30
27
105
50
25
53
1.5
80
126 30
27
105
65
16
70
2.0
105 165 45
12
90
80
16
85
2.0
130 201 45
12
90
100
12.5
104
2.0
155 241 45
12
90
Содержание TW61
Страница 18: ...11593963 06 04 2019 EN DE FR ES 18 WIKA operating instructions thermowell model TW61 EN...
Страница 34: ...11593963 06 04 2019 EN DE FR ES 34 WIKA Betriebsanleitung Schutzrohr Typ TW61 DE...
Страница 66: ...11593963 06 04 2019 EN DE FR ES 66 WIKA operating instructions thermowell model TW61...
Страница 67: ...WIKA operating instructions thermowell model TW61 11593963 06 04 2019 EN DE FR ES 67...