14399527.01 05/2021 EN/DE/FR/ES
29
WIKA operating instructions flow switch, model FSD-4
EN
Process connection
Standard
Thread
Probe length F
Insertion length L
Sealing
ISO 225-1
M18 x 1.5
45 mm [1.77 in]
52 mm [2.05 in]
FPM/FKM
DIN EN ISO 1179-2 (formerly DIN 3852-E)
G ¼ A
16 mm [0.63 in]
28 mm [1.1 in]
■
NBR (standard)
■
FPM/FKM
(option)
■
Without (option)
G ½ A
16 mm [0.63 in]
30 mm [1.18 in]
G ½ A
35 mm [1.38 in]
49 mm [1.93 in]
G ½ A
65 mm [2.65 in]
79 mm [3.11 in]
G ½ A
105 mm [4.13 in]
119 mm [4.69 in]
ANSI/ASME B1.20.1
¼ NPT
16 mm [0.63 in]
22 mm [0.87 in]
-
½ NPT
30 mm [1.18 in]
38 mm [1.5 in]
-
-
1)
Without
-
140 mm [5.51 in]
-
1)
For version with compression fitting
Output signal
Switch output 1
Switch output 2
Analogue output
IO-Link option
Output variant 1
x
x
-
x
Output variant 2
x
-
x
x
Output variant 3
x
x
x
x
Further details on: Output signal
Signal type
Switching output 1
■
Flow, PNP
■
Flow, NPN
Factory setting: Flow, PNP
Switching output 2
■
Flow, PNP
■
Flow, NPN
■
Temperature, PNP
■
Temperature, NPN
Factory setting: Flow, PNP
9. Specifications
Содержание FSD-4
Страница 68: ...14399527 01 05 2021 EN DE FR ES 68 WIKA operating instructions flow switch model FSD 4...
Страница 104: ...14399527 01 05 2021 EN DE FR ES 104 WIKA mode d emploi pour le capteur de d bit type FSD 4 FR...
Страница 138: ...14399527 01 05 2021 EN DE FR ES 138 WIKA operating instructions flow switch model FSD 4...
Страница 139: ...14399527 01 05 2021 EN DE FR ES 139 WIKA operating instructions flow switch model FSD 4...