5. Commissioning, operation
5. Commissioning, operation
5.1 Mounting preparation
■
Wire rope force transducers are sensitive measuring instruments and must be
handled with appropriate care.
■
There should be no visible damage on the rope.
■
The rope diameter and the corresponding rated loads can be found in the
specifications.
5.2 Mounting instructions
CAUTION!
Damage to the instrument through improper installation
■
The wire rope force transducer may only be subjected to loads in the
type of bearing provided.
■
Only mount the wire rope force transducer on the unloaded, stationary
rope.
■
There must be a minimum distance from the end of the rope of 100 mm.
■
The correct position of the rope in the wire rope force transducer must
always be ensured.
■
A rope that is not vertical can falsify the measuring result.
■
During mounting of the wire rope force transducer, the output signal
(force value) must always be monitored to avoid mechanical overload.
■
The torque of the screws should be taken from
the instructions in
Chapter 9 “Specifications”.