19
Operating instructions wire rope force transducer, model F9204
ADPR1X914116.01 04/2020 EN/DE
EN
9. Specifications
Model F9204
Rated load F
nom
t
1 / 2 / 3.5 / 5 / 10 / 20 / 30-40
Relative linearity error d
lin
±3 % F
nom
Relative span in unchanged mounting
position b
rg
±0.5 % F
nom
Relative reversibility error v
±0.5 % F
nom
Relative deviation of zero signal d
S, 0
±2 % F
nom
Relative creep, 30 min.
±0.05 % F
nom
Temperature effect on the zero signal TK
0
≤ ±0.25 %/10 °C
Temperature effect on the characteristic
value TK
C
≤ ±0.25 %/10 °C
Limit force F
L
150 % F
nom
Breaking force F
B
200 % F
nom
Material of the measuring body
Steel, nickel-plated
Rated temperature range B
T, nom
-10 … +60 °C
Service temperature range B
T, G
-20 … +80 °C
Input resistance R
e
780 ±10 Ω
Output resistance R
a
700 ±10 Ω
Insulation resistance R
is
≥ 5,000 MΩ/DC 50 V
Output signal (rated characteristic value)
C
nom
4 ... 20 mA (DC 0...10 V optional)
Electrical connection
Measuring cable ∅ 4 x 3,000 mm
Excitation voltage B
U, nom
24 V
Supply voltage
DC 12 ... 36 V
Ingress protection (per IEC/EN 60529)
IP66
Weight in kg
■
1 t
■
2 t
■
3.5 t
■
5 t
■
10 t
■
20 t
■
30-40 t
1.5
1.8
2.2
2.4
3.7
5.9
11.2