Kunststoffschweißtechnik
Starting
and
operating
Chapter 5
18.07.2013 Working
Instructions
WIDOS ESI 4000
Page 29 of 37
5.12. Traceability–how to activate information and pipe length
Display:
2nd line:
WIDOS ESI 4000
10.10.2011 10:10
Basic menu
Current date and time
Simultaneously press <- and Start> for next menu item
Display:
2nd line:
WIDOS ESI 4000
Please authorize
Only
possible with
general
authorization card
Authorize by bar code reading pen and
general
authorization card
Display:
2nd line:
WIDOS ESI 4000
10.10.2011 10:10
Current date and time is indicated
Press
<Start>
Display:
2nd line:
Authorization
yes
Press
<Start>
Display:
2nd line:
Name of project
WIDOS
--------------------
Current project name is indicated
Confirm by <Start>
Display:
2nd line:
Traceability
no
You may select traceability yes / no
Select “YES” with <+> if you require traceability
Only appears if traceability has been selected with yes.
Display:
2nd line:
pipe length
yes
You may select pipe length yes / no
Select pipe length yes by <+>