Kunststoffschweißtechnik
Starting
and
operating
Chapter 5
18.07.2013 Working
Instructions
WIDOS ESI 4000
Page 22 of 37
3 signals confirm the end of the welding process
Display:
2nd line:
Parameter OK 000s
Cooling time 00:00
Welding time is indicated
* Elapsed cooling time in min : sec is indicated
* Display changes:
R = 0.40Ohm (resistance at the end of the welding)
No = 0000 (joint number)
WIDOS------- (project name)
OD = 160 mm (outer pipe diameter)
Type: I FR (type of fitting)
E i t h e r :
The cooling can be aborted by <Start> e.g. for a further
welding
O r :
Read in start code from the cable with the barcode reading pen in order to
abort cooling.
The aborting may only be carried out if the welding connection remains tightly
clamped during the cooling time!
Caution danger of combustion! Welding connection is very hot!
At the end of the cooling time, the welding connection is unclamped, the
welding process is completed.
5.6. How to weld without fitting bar code
In general, the respective valid welding regulations have to be complied with
(ISO/CEN/DVS...).
Completely roll out welding cable, connect ESI 4000 plug into the fitting, if
necessary use adaptor.
Wear safety gloves to prevent burnings.
You may be injured by spillings.
Wear safety glasses during welding.
Only insert prepared (peeled) pipes into fitting!
Only use connections suiting the fitting type, care for a tight fit of the
connections!
Display:
2nd line:
no. 0000 Read in
fitting R=0.000hm
Actual joint number is indicated.
Actual resistance is indicated.
Read in the bar code from the
general
authorization card by the bar code
reading
pen
Display:
2nd line:
Voltage Heating
00 V