Kunststoffschweißtechnik
Operating and indicating elements
Chapter 4
14.02.2012
Working instructions WIDOS 2500 - 250 adjustable
Page 15 of 48
4.2. Elements at planer and heating element
No.
Denomination
Function
Planer
10 Switch on / off
- In order to switch the planer on / off
11 Button
- As soon as the planer is switched on and the button is
pressed, the planer turns round
12 Locking button
- by pressing it, the closing switch is maintained on „On“
Heating element
13 Switch on/off with lamp
- As soon as the heating element is switched on, it
is heated up.
- The red lamp lightens when the heating element is
connected to the mains.
14 Adjusting screw
- Adjusting of the temperature of the heating element.
15 Control lamp, green
- There are three different states:
•
On
: signalizes that the heating element is heated up at
the moment. The desired temperature has not been
reached yet.
•
Blinking
: the heating element temperature is
maintained by a certain pulse-position ratio.
•
Off
: Signalizes that the heating element is not heated
up at the moment or that it cools down.
10
11
13
14
15
12