900W PLANER ENG
throughout the entire cutting operation.
CAUTIONS:
When the planer is suspended with one hand after finishing the planning operation,
ensure that the cutting blades of the planer do not contact or come too near your body. Failure to do
so could result in serious injury.
6. BEVELING EDGES
The V-grooves in the front base allow a quick and easy beveling of work piece edges. To do this,
place the base with the V-groove on the edge of the workpiece and guide it along the edge. During
the beveling procedure, make sure you maintain a steady angle position (45°) and uniform feed
(See Fig 6).
7. REPLACING THE PLANER BLADE
1) Your blades have two cutting sides and are reversible. Dull and worn plane blades cannot be
reground and must be replaced. To reverse or replace the planer blades, using the spanner
provided loosen the 3 bolts approximately 1/2 turn clockwise (See Fig 7). Hold the blade clamp and
using a piece of wood slides the blade out of the blade clamp (See Fig 8).
NOTE:
there is no need to remove the blade clamp as this can change the factory settings for
cutting blade height control. Do not adjust the height adjusting screws.
2) Use a new blade or reverse the existing blade, then slide the blade into the blade clamp in the
connecting orientation (See Fig 9). Check the blade is equal in the clamp and the blade edge is
level with the base plate side.
3) Tighten the 3 bolts equally, then rotate the blade drum by a further 180° and repeat the
procedure assembling the second plane blade. Always replace both blades at the same time.
Otherwise, imbalance can cause vibrations and reduce the useful service life of the tool. Before
connecting the power cord, rotate by hand to check the blade drum is free to rotate.
WARNING:
Remove power cord from mains before making adjustments or changing blades.
CAUTIONS:
We recommend wearing safety gloves when replacing the plane blade, in order
to protect against injury from the sharp cutting edges of the plane blade.
8. REPLACING CARBON BRUSHES
When the carbon brushes need be replaced, use a screwdriver to remove the motor rear cover (See
Fig 10 & 11). Then take out the worn carbon brushes (See Fig 12 & 13), insert new ones into the brush
holder.
Both carbon brushes should be replaced at the same time. Use only identical carbon
brushes.
MAINTENANCE
WARNING:
Remove the plug from the socket before carrying out any adjustment, servicing
or maintenance.
1. Use of dull or damaged blades will result in reduced cutting efficiency and may cause overloading
of the motor. Replace the cutter blades as often as necessary. Always change the blades in pairs,
otherwise the resulting imbalance will cause vibration and shorten tool life.
2. Regularly inspect all mounting screws and ensure that they are properly tightened. Should any
of the screws be loose, retighten them immediately. Failure to do so could result in serious hazard.
3. Never use water or chemical cleaners to clean your power tool. Wipe clean with a dry cloth.
10
Содержание WD011810822
Страница 1: ...900W Planer WD011810822 ...
Страница 3: ...WD011810822 3 1 2 3 4 5 6 7 8 9 1 2 3 5 4 6 7 8 9 10 11 12 13 14 5 4 ...
Страница 4: ...WD011810822 4 10 11 12 13 ...
Страница 12: ...900W PLANER ENG EXPLOSIVE VIEW 12 ...
Страница 14: ......
Страница 15: ......
Страница 16: ...www widopt com MADE IN CHINA Copyright WIDO Machinery Co Ltd All rights reserved ...