background image

PARTS AND CONTROLS 

 

Auto Defrost Indicator 

In the event frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until 
the frost is evaporated. This happens when the appliance is operating in low temperatures (less than 53°F or 12°C), 
which affects the efficiency of the dehumidifier. When this happens, the Auto Defrost light will turn on and the ma-
chine will go into periodic defrost mode automatically. Defrost time may vary. If the dehumidifier freezes up, turn the 
appliance off for few hours and then restart. The appliance will not operate satisfactorily if the room temperature is 
below 41°F 

 

 

 

Display 

The display screen shows a number of different indications depending on the selection function.  

 

Shows the set % relative humidity level from 35%RH to 85%RH. 

 

Once the RH% is set, the set RH% will stay on the display for about 5 seconds then it will revert back to current 
RH%. 

 

Shows Auto Start and Auto Stop time from 0.0 hour to 24 hours. 

 

After the option settings are completed, the display shows the approximate room humidity level in a range of 
30%RH (Relative Humidity) to 90%RH . 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto Restart 

In the event of a power outage, appliance restarts at the previously set function mode and settings when power is 
restored (not applicable to Timer Function). 

 

 

Error Codes and Protection Code 

 

AS - Humidity Sensor Error 

Unplug the unit and plug it back in. 

 

ES - Temperature Sensor 

Error 

Unplug the unit and plug it back in. 

 

P2 - Drain Bucket Full 

Empty the drain bucket. 
Please make sure float moves freely and is not stuck . 

EC - Unit Malfunction 

Please make sure whether the environment temperature is 
between 41°F (5°C), and 96°F (35°C). 

 

E3 - Unit Malfunction 

Unplug the unit and plug it back in.  

Eb - Drain Bucket Error 

Drain bucket is removed or not positioned correctly. Make 
sure that the drain bucket is properly installed and the in 
right position.

 

Содержание RPD-321EW

Страница 1: ...R Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference M...

Страница 2: ...ned from your local municipal authority Thank you for choosing the Whynter Portable Dehumidifier Please follow the instructions provided in this user guide to obtain the very best performance from you...

Страница 3: ...SAFETY PRECAUTIONS 4 INTRODUCTION TECHNICAL DATA 5 PARTS AND CONTROLS 6 9 OPERATION INSTRUCTIONS 10 11 WATER DRAINAGE INSTRUCTIONS 12 13 MAINTENANCE 14 TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER 1...

Страница 4: ...adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements Do not use multip...

Страница 5: ...truct the air intake Keep curtains blinds or drapes closed during the sunniest part of the day Close all windows and doors Indoor relative humidity should ideally be kept between 35 RH and 60 RH depen...

Страница 6: ...6 PARTS AND CONTROLS OTHER ACCESSORIES 1 20 Continuous Gravity Drain hose 2 Continuous 6 75 Gravity Drain short hose adapter and screws...

Страница 7: ...bucket is full removed or the humidity level reaches the comfort range percentage Normal Mode Press the Mode Button to activate Normal Dehumidifying operation The Comfort and Continuous indicator ligh...

Страница 8: ...ours When the delay time set has elapsed the appliance switch es off To cancel the delayed switch off function set the time to 00 or turn off the appliance Timer Delay Switch On When the appliance is...

Страница 9: ...H will stay on the display for about 5 seconds then it will revert back to current RH Shows Auto Start and Auto Stop time from 0 0 hour to 24 hours After the option settings are completed the display...

Страница 10: ...es fungi and spores WARNING NEVER OPERATE THE DEHUMIDIFIER WITHOUT THE FILTER START OPERATION 1 Ensure that the appliance is connected to the power socket 2 Make sure the drain bucket is placed in pro...

Страница 11: ...maximum performance Allow at least 10 of air space on all sides of the appliance for good air circulation and 20 or more above the appliance NOTE Dehumidifiers working in a basement will have little o...

Страница 12: ...e water from the drain bucket and replace it back to the dehumidifier The drain bucket must be installed properly and securely seated for the dehumidifier to operate 5 The machine will restart when th...

Страница 13: ...the drain hose toward a drain or other suitable drain age outlet Make sure that there are no distortions with the hose that may stop the water flow 8 Place the drain bucket back into the unit and make...

Страница 14: ...the main unit NOTE Do not clean the bucket in a dishwasher 3 Cleaning the air filter To ensure the air intake is filtered properly and to assure that your dehumidifi er runs efficiently it is recommen...

Страница 15: ...r home is musty you will want to use your portable dehumidifier especially if you have respiratory trouble or allergies This unit can also help relieve symptoms by controlling the relative humidity in...

Страница 16: ...aced in a space that does not restrict air flowing into the rear coil or out of the front grille Set the RH level and the appliance will stop when the set RH is reached The dehumidifier runs but the r...

Страница 17: ...t voltage Call for service Only authorized person nel should replace damaged power cord or power plug If you want to remove more moisture set the unit on Continuous operation Empty drain bucket and in...

Страница 18: ...consumer misuse tampering or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by r...

Отзывы: