WATER DRAINAGE INSTRUCTIONS 

Using a portable dehumidifier requires that collected water be emptied frequently. Draining water from this unit 
can be done in 2 different methods: 

 

1. DRAIN BUCKET METHOD  

In order for water to be collected in the drain bucket, the continuous/gravity drain hose assembly should be re-
moved from the drain outlet.  Close the drain outlet with the rubber drain cover. 

 

1. When the bucket is full, the Full indicator light will light. The com-
pressor and fan will turn off, the Full indicator will light, and a P2 
code will be displayed. 

 

2. It is recommended to turn the unit off before removing the drain 
bucket. 

3. Grip the left and right handles of the drain bucket securely and 
carefully pull out the drain bucket. Do not put the drain bucket on 
the floor because the bottom of the bucket is not even which may 
cause the water to spill.  See Fig. 1 and Fig. 2. 

4. Remove the water from the drain bucket and replace it back to 
the dehumidifier. The drain bucket must be installed properly and 
securely seated for the dehumidifier to operate. 

5. The machine will restart when the drain bucket is restored in its 
correct position. If the unit was turned off prior to the removal of the 
drain bucket, press the Power button to restore operation. 

Fig. 1 

Fig. 2 

 

When you remove the drain bucket, do not touch any inside parts of the unit. Doing so may damage the prod-
uct and result to injury. 

 

Be sure to push the drain bucket gently all the way into the unit. Banging the bucket against anything or failing 
to push it in securely may cause the unit not to operate. 

 

Upon replacing the bucket, firmly push the bucket in place until it locks. There should be no gaps between the 
bucket and the dehumidifier.  

 

When the drain bucket is removed, the unit will beep 8 times and the digital display shows 

Eb

.  

Eb 

is an error 

code that indicates that the drain bucket is removed or not positioned correctly. Make sure that the drain buck-
et is properly installed and the in right position. 

Содержание RPD-321EW

Страница 1: ...R Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference M...

Страница 2: ...ned from your local municipal authority Thank you for choosing the Whynter Portable Dehumidifier Please follow the instructions provided in this user guide to obtain the very best performance from you...

Страница 3: ...SAFETY PRECAUTIONS 4 INTRODUCTION TECHNICAL DATA 5 PARTS AND CONTROLS 6 9 OPERATION INSTRUCTIONS 10 11 WATER DRAINAGE INSTRUCTIONS 12 13 MAINTENANCE 14 TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER 1...

Страница 4: ...adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements Do not use multip...

Страница 5: ...truct the air intake Keep curtains blinds or drapes closed during the sunniest part of the day Close all windows and doors Indoor relative humidity should ideally be kept between 35 RH and 60 RH depen...

Страница 6: ...6 PARTS AND CONTROLS OTHER ACCESSORIES 1 20 Continuous Gravity Drain hose 2 Continuous 6 75 Gravity Drain short hose adapter and screws...

Страница 7: ...bucket is full removed or the humidity level reaches the comfort range percentage Normal Mode Press the Mode Button to activate Normal Dehumidifying operation The Comfort and Continuous indicator ligh...

Страница 8: ...ours When the delay time set has elapsed the appliance switch es off To cancel the delayed switch off function set the time to 00 or turn off the appliance Timer Delay Switch On When the appliance is...

Страница 9: ...H will stay on the display for about 5 seconds then it will revert back to current RH Shows Auto Start and Auto Stop time from 0 0 hour to 24 hours After the option settings are completed the display...

Страница 10: ...es fungi and spores WARNING NEVER OPERATE THE DEHUMIDIFIER WITHOUT THE FILTER START OPERATION 1 Ensure that the appliance is connected to the power socket 2 Make sure the drain bucket is placed in pro...

Страница 11: ...maximum performance Allow at least 10 of air space on all sides of the appliance for good air circulation and 20 or more above the appliance NOTE Dehumidifiers working in a basement will have little o...

Страница 12: ...e water from the drain bucket and replace it back to the dehumidifier The drain bucket must be installed properly and securely seated for the dehumidifier to operate 5 The machine will restart when th...

Страница 13: ...the drain hose toward a drain or other suitable drain age outlet Make sure that there are no distortions with the hose that may stop the water flow 8 Place the drain bucket back into the unit and make...

Страница 14: ...the main unit NOTE Do not clean the bucket in a dishwasher 3 Cleaning the air filter To ensure the air intake is filtered properly and to assure that your dehumidifi er runs efficiently it is recommen...

Страница 15: ...r home is musty you will want to use your portable dehumidifier especially if you have respiratory trouble or allergies This unit can also help relieve symptoms by controlling the relative humidity in...

Страница 16: ...aced in a space that does not restrict air flowing into the rear coil or out of the front grille Set the RH level and the appliance will stop when the set RH is reached The dehumidifier runs but the r...

Страница 17: ...t voltage Call for service Only authorized person nel should replace damaged power cord or power plug If you want to remove more moisture set the unit on Continuous operation Empty drain bucket and in...

Страница 18: ...consumer misuse tampering or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by r...

Отзывы: