background image

PARTS AND CONTROLS 

4. Power Button 

Press to turn the dehumidifier on and off

 

 

5 - 6. Up and Down Buttons 

 

Humidity Set Control Buttons 

The humidity level can be set within a range of 35%RH(Relative Humidity) to 85%RH in 5% increments. For 
lower humidity level, press the Down button and set to a lower RH percentage value. For higher humidity 
level, press the Up button and set to a higher RH percentage value. Once the RH% is set, the set RH% will 
stay on the display for about 5 seconds then it will revert back to current RH%. 

 

Timer Set Control Buttons 

If Timer Button is pressed, use the Up and Down buttons to set the Auto Start and Auto Stop time from 0.0 
hour to 24 hours.

 

 

Energy Saver 

When the unit is running on normal operation, once the RH% is reached, the fan will still run continuously to avoid 
high start-up amperage which makes the unit energy-efficient . Please note that the fan may run continuously or 
shut off intermittently depending on the RH% and set humidity. 

 

7. Timer Button 

Press to activate the Timer delay feature, in conjunction with the Down and Up Buttons.  

 

Timer Delay Switch Off 

When the appliance is ON, press the Timer button to activate Auto-stop function and the Timer OFF 
light will come on. Set the desired time delay OFF hours by pressing the UP and DOWN buttons. The 
time increments are 1 hour up to 24 hours. When the delay time set has elapsed, the appliance switch-
es off. To cancel the delayed switch off function, set the time to “00” or turn off the appliance.

 

 

Timer Delay Switch On 

When the appliance is OFF, press the Timer button to activate Auto-start function and Timer ON light 
will come on. Set the desired time delay ON hours by pressing the UP and DOWN buttons. The time 
increments are 1 hour up to 24 hours. When the delay time set has elapsed, the appliance turns on. To 
cancel the delayed switch on function, set the time to “00” or turn off the appliance. 

 

Timer Delay Switch On and Off Sequence 

When the appliance is OFF, press the Timer button to activate Auto-start function and Timer light ON 
will come on. Set the desired time delay ON hours by pressing the UP and DOWN buttons. Once Timer 
Delay Switch On is placed, press the Timer button again to activate Auto-stop function and the Timer 
OFF light will come on. Set the desired time delay OFF hours by pressing the UP and DOWN buttons. 
When the delay time set has elapsed, the appliance switches off. To cancel the delayed switch off func-
tion, set the time to “00” or turn off the appliance. 

 

Bucket Full Indicator 

The appliance will run continuously until the set RH% is reached or when the drain bucket is full. When the drain 
bucket is full, the Full indicator light will illuminate and the dehumidifier will stop operating. Remove the water in the 
bucket with two hands, then place the drain bucket back to it's proper position and the machine will start operating 
again.  

 

Содержание RPD-321EW

Страница 1: ...R Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference M...

Страница 2: ...ned from your local municipal authority Thank you for choosing the Whynter Portable Dehumidifier Please follow the instructions provided in this user guide to obtain the very best performance from you...

Страница 3: ...SAFETY PRECAUTIONS 4 INTRODUCTION TECHNICAL DATA 5 PARTS AND CONTROLS 6 9 OPERATION INSTRUCTIONS 10 11 WATER DRAINAGE INSTRUCTIONS 12 13 MAINTENANCE 14 TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER 1...

Страница 4: ...adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements Do not use multip...

Страница 5: ...truct the air intake Keep curtains blinds or drapes closed during the sunniest part of the day Close all windows and doors Indoor relative humidity should ideally be kept between 35 RH and 60 RH depen...

Страница 6: ...6 PARTS AND CONTROLS OTHER ACCESSORIES 1 20 Continuous Gravity Drain hose 2 Continuous 6 75 Gravity Drain short hose adapter and screws...

Страница 7: ...bucket is full removed or the humidity level reaches the comfort range percentage Normal Mode Press the Mode Button to activate Normal Dehumidifying operation The Comfort and Continuous indicator ligh...

Страница 8: ...ours When the delay time set has elapsed the appliance switch es off To cancel the delayed switch off function set the time to 00 or turn off the appliance Timer Delay Switch On When the appliance is...

Страница 9: ...H will stay on the display for about 5 seconds then it will revert back to current RH Shows Auto Start and Auto Stop time from 0 0 hour to 24 hours After the option settings are completed the display...

Страница 10: ...es fungi and spores WARNING NEVER OPERATE THE DEHUMIDIFIER WITHOUT THE FILTER START OPERATION 1 Ensure that the appliance is connected to the power socket 2 Make sure the drain bucket is placed in pro...

Страница 11: ...maximum performance Allow at least 10 of air space on all sides of the appliance for good air circulation and 20 or more above the appliance NOTE Dehumidifiers working in a basement will have little o...

Страница 12: ...e water from the drain bucket and replace it back to the dehumidifier The drain bucket must be installed properly and securely seated for the dehumidifier to operate 5 The machine will restart when th...

Страница 13: ...the drain hose toward a drain or other suitable drain age outlet Make sure that there are no distortions with the hose that may stop the water flow 8 Place the drain bucket back into the unit and make...

Страница 14: ...the main unit NOTE Do not clean the bucket in a dishwasher 3 Cleaning the air filter To ensure the air intake is filtered properly and to assure that your dehumidifi er runs efficiently it is recommen...

Страница 15: ...r home is musty you will want to use your portable dehumidifier especially if you have respiratory trouble or allergies This unit can also help relieve symptoms by controlling the relative humidity in...

Страница 16: ...aced in a space that does not restrict air flowing into the rear coil or out of the front grille Set the RH level and the appliance will stop when the set RH is reached The dehumidifier runs but the r...

Страница 17: ...t voltage Call for service Only authorized person nel should replace damaged power cord or power plug If you want to remove more moisture set the unit on Continuous operation Empty drain bucket and in...

Страница 18: ...consumer misuse tampering or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by r...