TROUBLESHOOTING 

Problem 

Possible Causes 

Solutions 

The dehumidifier leaks.  

 

Continuous/gravity drain  hose 
is loose. 

 

Cracked drain bucket. 

 

Secure the drain hose. 

 

 

Contact Whynter Service Department. 

The dehumidifier does not 
operate. 

 

Power failure or outage. 

 

The automatic switch, line 
fuse, or breaker has been 
tripped. 

 
 
 

 

The power supply voltage is 
too low. 

 

The power cord is damaged. 

 
 

 

The dryness level you select-
ed has been reached. 

 

Drain bucket is full or not  
positioned properly. 

 

Restore the power supply. 

 

Flip the switch / change the fuse / turn the 
breaker back on. Also note that you may 
have too many appliances drawing power 
on one circuit, you may need to move the 
other appliances to another circuit. 

 

Move the appliance onto another circuit 
with the correct voltage. 

 

Call for service. Only authorized person-
nel should replace damaged power cord 
or power plug. 

 

If you want to remove more moisture, set 
the unit on Continuous operation. 

 

Empty drain bucket and insert the bucket 
to the appliance properly. 

Water on floor. 

 

Drain bucket is not installed 
properly. 

 

Drain hose connection may be 
loose or not installed properly. 

 

Install the drain bucket securely. 

 

 

Make sure that the drain hose is securely 
installed in the drain outlet. 

 

For Drain Bucket method, make sure that 
the continuous drain assembly is not in-
stalled and rubber drain cover is in place. 

 

For Continuous/Gravity Drain method, 
make sure the hose is securely fastened 
to prevent leakage. Direct the drain hose 
toward a drain or other suitable drainage 
outlet.  

Many common portable dehumidifiers problems are easily resolved. Try the troubleshooting suggestions 
below to see if the problems can be resolved before having to contact the service department. 

Содержание RPD-321EW

Страница 1: ...R Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference M...

Страница 2: ...ned from your local municipal authority Thank you for choosing the Whynter Portable Dehumidifier Please follow the instructions provided in this user guide to obtain the very best performance from you...

Страница 3: ...SAFETY PRECAUTIONS 4 INTRODUCTION TECHNICAL DATA 5 PARTS AND CONTROLS 6 9 OPERATION INSTRUCTIONS 10 11 WATER DRAINAGE INSTRUCTIONS 12 13 MAINTENANCE 14 TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER 1...

Страница 4: ...adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements Do not use multip...

Страница 5: ...truct the air intake Keep curtains blinds or drapes closed during the sunniest part of the day Close all windows and doors Indoor relative humidity should ideally be kept between 35 RH and 60 RH depen...

Страница 6: ...6 PARTS AND CONTROLS OTHER ACCESSORIES 1 20 Continuous Gravity Drain hose 2 Continuous 6 75 Gravity Drain short hose adapter and screws...

Страница 7: ...bucket is full removed or the humidity level reaches the comfort range percentage Normal Mode Press the Mode Button to activate Normal Dehumidifying operation The Comfort and Continuous indicator ligh...

Страница 8: ...ours When the delay time set has elapsed the appliance switch es off To cancel the delayed switch off function set the time to 00 or turn off the appliance Timer Delay Switch On When the appliance is...

Страница 9: ...H will stay on the display for about 5 seconds then it will revert back to current RH Shows Auto Start and Auto Stop time from 0 0 hour to 24 hours After the option settings are completed the display...

Страница 10: ...es fungi and spores WARNING NEVER OPERATE THE DEHUMIDIFIER WITHOUT THE FILTER START OPERATION 1 Ensure that the appliance is connected to the power socket 2 Make sure the drain bucket is placed in pro...

Страница 11: ...maximum performance Allow at least 10 of air space on all sides of the appliance for good air circulation and 20 or more above the appliance NOTE Dehumidifiers working in a basement will have little o...

Страница 12: ...e water from the drain bucket and replace it back to the dehumidifier The drain bucket must be installed properly and securely seated for the dehumidifier to operate 5 The machine will restart when th...

Страница 13: ...the drain hose toward a drain or other suitable drain age outlet Make sure that there are no distortions with the hose that may stop the water flow 8 Place the drain bucket back into the unit and make...

Страница 14: ...the main unit NOTE Do not clean the bucket in a dishwasher 3 Cleaning the air filter To ensure the air intake is filtered properly and to assure that your dehumidifi er runs efficiently it is recommen...

Страница 15: ...r home is musty you will want to use your portable dehumidifier especially if you have respiratory trouble or allergies This unit can also help relieve symptoms by controlling the relative humidity in...

Страница 16: ...aced in a space that does not restrict air flowing into the rear coil or out of the front grille Set the RH level and the appliance will stop when the set RH is reached The dehumidifier runs but the r...

Страница 17: ...t voltage Call for service Only authorized person nel should replace damaged power cord or power plug If you want to remove more moisture set the unit on Continuous operation Empty drain bucket and in...

Страница 18: ...consumer misuse tampering or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by r...

Отзывы: