30411-0-0612
Page 34
Wiring
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the
National Electrical Code ANSI/NFPA No. 70
, if an external
electrical source is utilized.
This appliance is equipped with a
three-prong [grounding] plug for your protection against shock
hazard and should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the grounding
prong from this plug.
For an ungrounded receptacle, an adapter,
which has two prongs and a wire for grounding, can be purchased,
plugged into the ungrounded receptacle and its wire connected
to the receptacle mounting screw. With this wire completing the
ground, the appliance cord plug can be plugged into the adapter
and be electrically grounded.
CAUTION
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation. Verify
proper operation after servicing.
Oiling Blower Motor
The blower motor does not have oiling holes. Do not attempt to
oil the blower motor.
WARNING
Unplugging of blower accessory will not stop the heater
from cycling. To turn off gas to the unvented heater: Push
in gas control knob slightly and turn clockwise to “OFF.”
Do not force.
OPTIONAL BLOWER INSTALLATION INSTRUCTIONS (cont.)
30. Attach rear log support to inner casing with three three
10 x 1/2" screws from step 4.
31. Place and align blower diverter on top of inner casing. Attach
deflector to top of inner casing with two 10 x 1/2" screws. See
Figure 34.
32. Replace bottom louver.
33. Replace upper louver.
34. Replace screen front by lifting upward on screen front.
35. Attach wiring diagram label to inside of heater base.
Figure 34
Figure 35