![White Knight Heateflex Aquarius Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/white-knight/heateflex-aquarius/heateflex-aquarius_owners-manual_976071018.webp)
Copyright © 2020 White Knight Fluid Handling | A Graco company
P: 626.599.8566 |
|
https://wkfluidhandling.com
Aquarius DIW Heaters Owner’s Manual
Ver. 1.0.0 | 29 Apr 2020 | P. 16
Subject to change without notice
Verify that the specific sanitation method
is compatible with the O-ring material
selected. The table (
right
) indicates
examples of acceptable means of
sanitation with a given O-ring material
for Aquarius
®
systems. Consult factory
to verify other means.
We recommend that users follow proper
decontamination and decommissioning
procedures when removing Aquarius
®
systems from service. Please contact us
for recommendations on proper disposal
or qualified dismantlers in your area.
Aquarius
®
systems features an Auto Purge option that reduces the potential of bacteria
growth in the DIW or process fluid and Aquarius
®
plumbing system. The purge feature
of the Aquarius
®
can be activated or used three different ways:
1. Automated using the PF3000 control logic.
2. Manually through the use of the HMI/Touch screen interface.
3. Remotely through a communications interface.
Heating DIW or process fluid is not permitted while the system is actively purging.
Please refer to the PF3000 controller manual for more information on the operation of
the Auto Purge feature and HMI/Touch screen operation of the Aquarius
®
system. The
Auto Purge feature is not available on Aquarius
®
systems with the recirculation feature.
10. Aquarius
®
with Auto Purge (Optional)
Item
Material of construction
Cabinet
Carbon Steel Powder Coated
Drip Pan
Polypropylene (PP)
Wire Insulation
Polyvinyl Chloride (PVC)
Tetrafluoroethylene (TFE)
Plumbing
Fluorinated Ethylene Propylene (FEP)
Perfluoro-alkoxy Alkanes (PFA)
Polyvinylidene Fluoride (PVDF)
Polytetrafluoroethylene (PTFE)
O-Ring Material Approved Sanitization Methods
Chemraz 505
Carbon Steel Powder Coated
Viton
H2O2 and HCl
Aquarius
®
systems with the optional recirculation feature have a built-in recirculation
system and are equipped with an ultra–pure PFA-PTFE bearing-less pump, pump air
cooling system, and safety interlocks. The pump is controlled by a PLC. The Aquarius
®
recirculation feature is optimized for precise DIW temperature control during recirculation,
and provides hot DIW at temperature on-demand. The recirculation feature reduces heat
up time by implementing controlled heating at instances when demand is not required.
When demand is needed, the Aquarius
®
system returns to single pass mode and is ready
to provide DIW at the specified temperature.
In addition to saving process time, Aquarius
®
recirculation feature also reduces DIW usage
which is an added cost savings for waste water and energy. The ability of the Aquarius
®
to
provide an instant supply of heated DIW negates the requirement for a trickle flow, which
is commonly used by DIW heaters to maintain pre-demand water temperature. Aquarius
®
recirculation feature will also discourage bacteria growth from forming in the process fluid
and Aquarius
®
plumbing, which is essential in maintaining high purity requirements.
11. Aquarius
®
with Recirculation (Optional)