![WhisperKool Platinum Split Twin Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/whisperkool/platinum-split-twin/platinum-split-twin_owners-manual_975286009.webp)
www.whisperkool.com | Page 7
Platinum Twin
WALL-MOUNTED TWIN SPECIFICATIONS
Model
9000 Master Evaporator
(Fan Coil Unit)
9000 Slave Evaporator
(Fan Coil Unit)
Cellar Size (cu. ft.)
Approx. 3000
Approx. 3000
Dimensions
20.5”W x 15.5”H x 16.1”D
20.5”W x 15.5”H x 16.1”D
BTUh with 90°F air enter-
ing the condenser coil
8500
8500
CFM
270
270
Refrigerant
R-404a
R-404a
Voltage Rating
115V (15-amp dedicated circuit required)
115V (15-amp dedicated circuit required)
Weight (lbs)
80
80
AMPS
(Starting/Running)
2/1
2/1
dBA
58.5
58.5
Drain Line
1/2” ID clear plastic tubing (not provided)
Installation
Evaporator units are installed in the cellar. Condensing unit is installed outside in a protective
enclosure.
Thermostat
Aftermarket (24V thermostat not included)
Temp. Delta
55°F temperature differential between cellar environment and condensing unit intake air
Warranty
2 years (parts and labor)
Evaporator unit (fan coil unit)