Platinum Twin
Initial Start-Up
Set the thermostat to COOL and fan switch to AUTO.
Lower the set point to the desired cellar temperature. (A
temperature of 55°F is the recommended set point.) See
thermostat instructions for details.
Normal System Cycle
The thermostat should turn the cooling system on when
it senses a temperature one (1) degree higher than the set
point. See thermostat instructions for details.
Anti-Short Cycle
Most thermostats have a safety feature that will prevent
the condensing unit from cycling on and off within a short
period of time. During the anti-short cycle, the condensing
unit will typically remain off for 5-7 minutes. See thermostat
instructions for details.
Fan Operation
If the fan switch on the thermostat is in the AUTO position, it
will run only during the cooling cycle. If the fan switch on the
thermostat is in the ON position, the fan will continuously run
until the switch is set back to the AUTO position.
Anti-Frost
Systems equipped with a 24V thermostat conversion kit do
NOT have an anti-frost feature. To reduce the possibility of the
evaporator coil icing up, avoid setting the thermostat lower
than 55°F.
NOTE: To ensure correct system operation, the 24V thermostat
must be placed inside the wine cellar, preferably in a central
location away from any airflow.
SYSTEM OPERATION
The cooling system is equipped with the hardware needed to support a 24-volt air conditioning thermostat (not included).