 Platinum Twin

System does not power up/run

Possible cause

Solution

Batteries on thermostat have lost their charge

Change batteries

Thermostat wired incorrectly

Check wiring on 24V thermostat and correct

Wiring issue at master evaporator unit

Contact Customer Service for troubleshooting

24V transformer in master evaporator unit has failed

Contact Customer Service for troubleshooting

Evaporator fans run continuously

Possible cause

Solution

Fan switch on thermostat set to "on"

Set fan switch to the "auto" position

Fan relay in thermostat or 24V conversion kit stuck on

Call Customer Service for details on how to perform the bypass plug 
test

Units equipped with the 24V Thermostat Conversion Kit: 

Содержание Platinum Split Twin

Страница 1: ...PLATINUM SPLIT TWIN OWNER S MANUAL The Coolest Thing In Wine Storage 24V Thermostat Conversion Kit Option ...

Страница 2: ...responsible for printing or clerical errors WhisperKOOL reserves the right to make corrections or improvements to the information provided and to the related hardware at any time without notice Vinothèque and WhisperKOOL are registered trademarks and ECE is a trademark of WhisperKOOL All rights reserved Mention of third party products is for informational purposes only and constitutes neither an e...

Страница 3: ...porator Unit 5 Fully Ducted Evaporator Unit 6 Wall Mounted Twin Specifications 7 Fully Ducted Twin Specifications 8 Condensing Unit Quick Reference Guide 9 Preparing the Wine Cellar 10 System Operation 13 Troubleshooting Guide 15 Maintenance Schedule 18 Technical Assistance Accessories 19 Installation Terms and Conditions 20 ...

Страница 4: ...designed for one purpose only to maintain the optimal temperature and humidity levels conducive to the proper storage and aging of fine wines This system produces minimal in cellar noise and has the most lenient exhaust requirements An exterior housing is required for outdoor condensing unit installations How Does the Cooling System Work Similar to the air conditioning systems used for homes the e...

Страница 5: ... The system is intended for use in properly designed and constructed wine cellars Hire a professional wine storage consultant with a valid contractor s license to build your wine cellar 6 WhisperKOOL requires that all split systems be installed by a certified HVAC R technician only NATE or equivalent is recommended 7 It is vital that the units be set apart and oriented so that the return air from ...

Страница 6: ...mishandling Write any discrepancy or visual damage on the bill of lading before signing Allow the condensing unit to sit for 24 hours prior to start up The condensing unit can be placed in the installation location piped and evacuated during this time NOTE WhisperKOOL units are manufactured in the USA and tested prior to shipment Review the packing slip to verify contents Check the model number to...

Страница 7: ...routing for optional 24 volt thermostat NOT INCLUDED INSIDE CELLAR Option 2 THROUGH THE WALL Option 1 Knockout for wiring Knockout for wiring Knockout for drain line Line set knockout Mounting keyholes 4 Line set knockout Knockout for drain line Wall Mounted Front Side View Wall Mounted Rear Side View Return air Supply air ...

Страница 8: ...air Fully Ducted Front Side View INSIDE CELLAR Option 2 THROUGH THE WALL Option 1 Knockout for wiring Knockout for wiring Knockout for drain line Line set knockout Mounting keyholes 4 Line set knockout Knockout for drain line Fully Ducted Rear Side View REAR VIEW ...

Страница 9: ...R 404a Voltage Rating 115V 15 amp dedicated circuit required 115V 15 amp dedicated circuit required Weight lbs 80 80 AMPS Starting Running 2 1 2 1 dBA 58 5 58 5 Drain Line 1 2 ID clear plastic tubing not provided Installation Evaporator units are installed in the cellar Condensing unit is installed outside in a protective enclosure Thermostat Aftermarket 24V thermostat not included Temp Delta 55 F...

Страница 10: ...uct 200 200 Refrigerant R 404a R 404a Voltage Rating 115V 15 amp dedicated circuit required 115V 15 amp dedicated circuit required Weight lbs 80 80 AMPS Starting Running 2 1 2 1 dBA 58 5 58 5 Drain Line 1 2 ID clear plastic tubing not included Installation Use 8 supply and 10 return insulated ducting Maximum duct length is 25 total duct feet per evaporator Thermostat Aftermarket 24V thermostat not...

Страница 11: ...pprox 3000 Dimensions 20 5 W x 15 5 H x 16 1 D BTUh with 90 F air enter ing the condenser coil 8500 wall mount 7850 fully ducted CFM 270 Refrigerant R 404a Condensing Unit HP 3 4 Voltage Rating 208 230 60 1 15 amp dedicated circuit required Weight lbs 67 AMPS Starting Running 27 7 3 Installation Evaporator units are installed in the cellar or up to 25 ducted feet away Condensing unit is installed ...

Страница 12: ... value the more resistant the insulation is to conducting heat and the more consistent your wine cellar s temperature will be Using higher R values in insulation will lower your operating costs and WhisperKOOL unit run time R 13 is the recommended minimum R 19 is preferred for interior cellar walls and R 30 for ceilings and exterior walls Vapor Barrier Water vapor creates its own pressure separate...

Страница 13: ...e 3 feet of horizontal clearance in every direction around the units five feet is ideal The air blown by the fans needs to circulate and either dissipate or absorb heat from the space The system will operate more efficiently with a greater amount of air to exchange NOTE Avoid attempting to camouflage the units This will restrict airflow and thus the system s ability to work efficiently NOTE For du...

Страница 14: ...ng unit If ventilation is inadequate the exhaust will heat up the area or room and adversely affect the systems ability to cool In some cases it may be advisable to install a vent fan to dissipate heat within the exhaust area on the condensing side of the system However you must have a fresh air inlet as well NOTE If you are unsure about having adequate ventilation in your install location please ...

Страница 15: ...t will typically remain off for 5 7 minutes See thermostat instructions for details Fan Operation If the fan switch on the thermostat is in the AUTO position it will run only during the cooling cycle If the fan switch on the thermostat is in the ON position the fan will continuously run until the switch is set back to the AUTO position Anti Frost Systems equipped with a 24V thermostat conversion k...

Страница 16: ...Page 14 1 800 343 9463 PT 102417 NOTES ...

Страница 17: ...e there is 110V 120V Thermostat not calling for cooling Adjust thermostat to a lower temperature Faulty thermostat or wiring Call Customer Service at 1 800 343 9463 Cellar temperature is too warm Possible cause Solution The temperature of the room to which the condensing unit exhausts exceeds 110 F Intake temperature needs to drop below 110 F The system is undersized for the cellar Order correctly...

Страница 18: ... Compressor and or starting components faulty Please contact the installing technician to troubleshoot Compressor may have overheated Shut system off for 1 hour to allow compressor to cool Turn back on and check for cooler air flow out If compressor runs check for and clean condenser coil as possible cause of compressor overheating If problem repeats contact your installing technician to assist wi...

Страница 19: ...ator unit Contact Customer Service for troubleshooting 24V transformer in master evaporator unit has failed Contact Customer Service for troubleshooting Evaporator fans run continuously Possible cause Solution Fan switch on thermostat set to on Set fan switch to the auto position Fan relay in thermostat or 24V conversion kit stuck on Call Customer Service for details on how to perform the bypass p...

Страница 20: ... are above the waterline if draining into a vessel Quarterly 1 Use a vacuum with brush attachment to clean coils be careful not to crush coil fins when cleaning 2 Change duct filters if the system is ducted Annually 1 Inspect for corrosion 2 Check wiring connections and integrity of cords 3 Pour a 50 50 bleach solution into the drain lines every spring ...

Страница 21: ...port whisperkool com Phone 209 466 9463 US Toll Free 1 800 343 9463 Fax 209 466 4606 WhisperKOOL offers accessories to enhance and customize your wine cooling unit Condensate Pump Kit The condensate pump kit automatically removes water that drips out of the evaporator units drain lines The pump is controlled by a float switch mechanism that turns the pump on when approximately 2 of water collects ...

Страница 22: ...anty throughout the warranty period If the Split Startup Checklist is incomplete Purchaser will be informed they have five days to complete the Split Startup Checklist and re submit to WhisperKOOL The Split Startup Checklist will be reviewed again and if denied Purchaser will be informed that they have 10 business days for corrective action Failure to register the Product may result in loss of war...

Страница 23: ... not follow the Product installation requirements stated herein and in the owner s manual 9 Removing the rivets from the Product s unit housing without prior authorization from WhisperKOOL voids this limited warranty 10 The End User must first contact WhisperKOOL Customer Service by telephone at 1 800 343 9463 prior to attempting service on any Product still under the limited warranty else the lim...

Страница 24: ...rmined that it is an installation error or other reason all costs including shipping will be the responsibility of the End User The following items are not covered under any warranty and are the sole responsibility of the End User A End Users should satisfy themselves that the Product they are purchasing is suitable for their particular needs and requirements and thus no responsibility will be pla...

Страница 25: ... court of competent jurisdiction to be invalid illegal or otherwise unenforceable such provision will to the extent so held be deemed severed from the contract of sale between Purchaser and WhisperKOOL and all of the other non severed provisions will remain in full force and effect D Governing Law Choice of Forum The laws of the State of California without regard for conflicts of law shall govern ...

Страница 26: ...WhisperKOOL 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www whisperkool com ...

Отзывы: