background image

6

24 in.

2

(155 cm

2

)

48 in.

2

(310 cm

2

)

1"

(25 mm)

1"

(25 mm)

5"

(102 mm)

3"

(76 mm)

34" recommended

(864 mm)

18" min.

(457 mm)

3"

(76 mm)

Back view:

INSTALL LEvELINg LEgS

1. 

Prepare dryer for leveling legs

To avoid damaging floor, use a large flat piece of cardboard 

from dryer carton; place under entire back edge of dryer. 

Firmly grasp dryer body (not console panel) and gently lay 

dryer down on cardboard.

6

1

/

2

"

(165 mm)

30

1

/

2

"

(775 mm)

6

1

/

4

"

(159 mm)

6

1

/

4

"

(159 mm)

14

1

/

2

"

(368 mm)

1

1

/

2

"

(36 mm)

4

1

/

4

"

(108 mm)

Mobile home - Additional installation requirements: 

This dryer is suitable for mobile home installations.  

The installation must conform to the Manufactured  

Home Construction and Safety Standard, Title 24 CFR,  

Part 3280 (formerly the Federal Standard for Mobile home 

construction and Safety, Title 24, HUD Part 280) or Standard 

Mobile Homes, CAN/CSA-Z240 MH.

Mobile home installations require: 

All dryers:

Metal exhaust system hardware, available for purchase  

 

from your dealer. For further information, see “Assistance  

or Service” section in your “Use and Care Guide”.

Special provisions must be made in mobile homes  

 

to introduce outside air into dryer. Openings (such  

as a nearby window) should be at least twice as large  

as dryer exhaust opening.

For gas dryers mobile home installations:

Mobile Home Installation Hold-down Kit Part Number 

 

346764 is available to order. For further information, see  

“Assistance or Service” section in your “Use and Care 

Guide”.

NOTE: 

Most installations require a minimum 5" (102 mm) 

clearance behind the dryer for the exhaust vent with elbow.  

See “Venting Requirements”.

Installation spacing for recessed area or closet 

installation

The dimensions shown below are for the recommended spacing for 

this dryer.

Additional spacing should be considered for ease of 

 

installation and servicing.

Additional clearances might be required for wall, door, and 

 

floor moldings, and dryer venting.

Additional spacing of 1" (25 mm) on all sides of the dryer is 

 

recommended to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings 

 

in the top and bottom of the door are required. Louvered doors 

with equivalent ventilation openings are acceptable.Companion 

appliance spacing should also be considered.

Recommended installation spacing:

Содержание Vantage WGD7990X

Страница 1: ... installation _ ________________________________ Installateur _______________________________________ Numéro de modèle _________________________________ Numéro de série ___________________________________ NOTES CONCERNANT L INSTALLATION Table des matières SÉCURITÉ DE LA SÉCHEUSE 16 EXIGENCES D INSTALLATION 18 Outillage et pièces 18 Exigences d emplacement 19 Installation des pieds de nivellement 2...

Страница 2: ...2 DRYER SAFETY ...

Страница 3: ...3 When discarding or storing your old clothes dryer remove the door ...

Страница 4: ...nd read Electrical Requirements and Venting Requirements before purchasing parts Check code requirements Some codes limit or do not permit installing dryer in garages closets mobile homes or sleeping quarters Contact your local building inspector Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom you purchased your dryer For further inf...

Страница 5: ...ided 20 100 psi 138 690 kPa for best performance For a garage installation you will need to place the dryer at least 18 460 mm above the floor If you live in a hard water area use of a water softener is recommended to control the buildup of scale through the water system in the dryer IMPORTANT Do not operate your dryer at temperatures below 45 F 7 C At lower temperatures the dryer might not shut o...

Страница 6: ...Care Guide Special provisions must be made in mobile homes to introduce outside air into dryer Openings such as a nearby window should be at least twice as large as dryer exhaust opening For gas dryers mobile home installations Mobile Home Installation Hold down Kit Part Number 346764 is available to order For further information see Assistance or Service section in your Use and Care Guide NOTE Mo...

Страница 7: ...wall receptacle The cord is 5 ft 1 52 m long Be sure wall receptacle is within reach of dryer s final location 4 wire receptacle 14 30R If using a replacement power supply cord it is recommended that you use Power Supply Cord Replacement Part Number 9831317 For further information please reference service numbers located in Assistance or Service section of your Use and Care Guide 15 16 33 6 mm GRO...

Страница 8: ... Do not modify the plug provided with the dryer if it will not fit the outlet have a proper outlet installed by a qualified electrician GAS SUPPLY REQUIREMENTS GAS TYPE Natural Gas This dryer is equipped for use with Natural gas It is design certified by CSA International for LP propane or butane gases with appropriate conversion Your dryer must have the correct burner for the type of gas in your ...

Страница 9: ...arger tubing and a different size adapter fitting If your dryer has been converted to use LP gas 3 8 LP compatible copper tubing can be used If the total length of the supply line is more than 20 ft 6 1 m use larger pipe NOTE Pipe joint compounds that resist the action of LP gas must be used Do not use TEFLON tape Must include shut off valve In the U S A An individual manual shut off valve must be...

Страница 10: ...ure exhaust hood is not plugged with lint Replace plastic or metal foil vents with rigid metal or flexible metal vents Review Vent System Chart and if necessary modify existing vent system to achieve best drying performance Louvered Hood 90 elbow Angled Hood Box Hood 45 elbow Exhaust hoods Elbows Recommended Styles Recommended Styles 45 elbows provide better airflow than 90 elbows Clamps Use clamp...

Страница 11: ...astened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home Terminate the exhaust vent outside Mobile Home Exhaust installation Determine vent path Select route that will provide straightest and most direct path outdoors Plan installation to use fewest number of elbows and turns When using elbows or making turns allow as much room as possible Ben...

Страница 12: ...eak Correct any leaks found A Closed valve B Open valve MAKE GAS CONNECTION Install Vent System 1 Install exhaust hood 12 min 305 mm 12 min 305 mm Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood 2 Connect vent to exhaust hood Vent must fit over the exhaust hood Secure vent to exhaust hood with 4 102 mm clamp Run vent to dryer location using straight...

Страница 13: ...e short hose Screw on coupling by hand until it is seated on connector Fig A Fig B Tighten couplings 3 Using pliers tighten the couplings with additional two thirds turn NOTE Do not overtighten Damage to the coupling can result Attach long hose to Y connector and tighten couplings 4 One end of the long hose has a wire mesh strainer inside the coupling Attach this end to the Y connector Attach wash...

Страница 14: ...ng a 4 102 mm clamp connect vent to exhaust outlet in dryer If connecting to existing vent make sure vent is clean Dryer vent must fit over dryer exhaust outlet and inside exhaust hood Check that vent is secured to exhaust hood with a 4 102 mm clamp 2 Move dryer to final location Move dryer to final location Avoid crushing or kinking vent After dryer is in place remove cardboard from under the dry...

Страница 15: ...a damp cloth to remove any dust q Read Dryer Use in your Use and Care Guide q If you live in a hard water area use of a water softener is recommended to control the buildup of scale through the water system in the dryer Over time the buildup of lime scale may clog different parts of the water system which will reduce product performance Excessive scale buildup may lead to the need for certain part...

Страница 16: ...16 Sécurité de la sécheuse ...

Страница 17: ...17 Pour mettre l ancienne sécheuse au rebut ou pour la remiser enlever la porte ...

Страница 18: ...5 mm ou clé à douille à tête hexagonale Pince à dénuder les fils pour les installations à raccordement direct Cisaille de ferblantier pour l installation d un nouveau conduit Pistolet à calfeutrage et composé de calfeutrage pour l installation d un nouveau conduit d évacuation Brides de serrage pour conduit d évacuation Tourne écrou de 1 4 recommandé Outils nécessaires aux installations au gaz Clé...

Страница 19: ...ge et une pression d eau de 20 à 100 lb po 137 9 à 689 6 kPa L alimentation en eau de la laveuse peut être utilisée avec le connecteur en Y et le tuyau court si nécessaire fournis 20 à 100 lb po 138 à 690 kPa pour un rendement optimal Pour une installation dans un garage vous devez placer la sécheuse à au moins 18 46 cm au dessus du plancher Si l on réside dans une région où l eau est dure l emplo...

Страница 20: ...1 25 mm 5 102 mm 3 76 mm 34 recommended 864 mm 18 min 457 mm 3 76 mm Installation dans une maison mobile exigences supplémentaires Cette sécheuse peut être installée dans une maison mobile L installation doit être conforme aux critères de la version la plus récente de la norme suivante des É U Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 anciennement Federal Standard f...

Страница 21: ...e que la prise murale se trouve à proximité de l emplacement définitif de la sécheuse Prise murale à 4 fils 14 30R Lorsqu on utilise un cordon d alimentation de rechange il est recommandé d utiliser le cordon d alimentation de rechange pièce n 9831317 Pour plus de renseignements consulter les numéros de service indiqués à la section Assistance ou service du Guide d utilisation et d entretien INSTA...

Страница 22: ...ctricien ou un technicien ou un personnel qualifié Ne pas modifier la fiche de branchement fournie avec la sécheuse si la fiche ne correspond pas à la configuration de la prise de courant demander à un électricien qualifié d installer une prise de courant appropriée Pour une sécheuse reliée à la terre et connectée par un cordon Cette sécheuse doit être reliée à la terre En cas de mauvais fonctionn...

Страница 23: ...1 8 m maximum de la sécheuse conformément au Code national d alimentation au gaz ANSI Z223 1 L emplacement doit être facile à atteindre pour ouvrir et fermer la sécheuse Au Canada Un robinet d arrêt individuel manuel doit être installé conformément à la norme B149 1 du Code des installations au gaz naturel ou propane On recommande que le robinet d arrét manuel individuel soit installé à 6 pi 1 8 m...

Страница 24: ... GAZ DE LA SÉCHEUSE La canalisation d arrivée de gaz sortant à l arrière de la sécheuse est dotée d un filetage mâle de 3 8 A A 3 8 NPT dryer pipe 5 3 4 159 mm 1 1 2 38 mm A Conduit NPT de la sécheuse de 3 8 Si la sécheuse est montée sur un piédestal prévoir 10 254 mm ou 15 5 394 mm de plus à partir du sol pour la hauteur de la canalisation d arrivée de gaz en fonction du modèle de piédestal Pour ...

Страница 25: ...des vis ou avec tout autre dispositif de serrage qui se prolonge à l intérieur du conduit et où la charpie risque de s accrocher Ne pas utiliser de ruban adhésif pour conduit Coude à 90 Coude à 45 Clapet à persiennes Clapet incliné Clapet de type boîte Clapets de décharge Styles recommandés Doit se situer à au moins 12 305 mm au dessus du sol ou de tout objet susceptible d obstruer l évacuation pa...

Страница 26: ... évacuation vers l extérieur Installation du système d évacuation en résidence mobile Déterminer l itinéraire d acheminement du conduit Choisir l itinéraire d acheminement vers l extérieur qui sera le plus direct et le plus rectiligne Planifier l installation de façon à introduire un nombre minimal de coudes et de changements de direction Si des coudes ou changements de direction sont utilisés pré...

Страница 27: ... et l emplacement de la canalisation d alimentation A Raccord flexible de gaz de 3 8 B Conduit de la sécheuse de 3 8 C Coude de 3 8 par 3 8 D Adaptateur entre le conduit et le joint conique de 3 8 INSTALLATION DU CIRCUIT D ÉVACUATION 12 min 305 mm 12 min 305 mm Installer le clapet d évacuation 1 Installer un clapet d évacuation et calfeutrer l ouverture murale à l extérieur autour du clapet d évac...

Страница 28: ...arrêt du gaz ouvert 3 A B A Robinet fermé B Robinet ouvert Ouvrir le robinet d arrêt de la canalisation d alimentation le robinet est ouvert lorsque la manette est parallèle à la canalisation de gaz Vérifier ensuite tous les raccordements en les badigeonnant d une solution de détection des fuites non corrosive approuvée L apparition de bulles indique la présence d une fuite Réparer toute fuite éve...

Страница 29: ...er l autre extrémité du long tuyau à l électrovanne située au bas du panneau arrière de la sécheuse Visser le raccord à la main jusqu à ce qu il repose sur le connecteur de l électrovanne Terminer le serrage des raccords de deux tiers de tour supplémentaire avec une pince REMARQUE Ne pas serrer excessivement Le raccord risque d être endommagé Fixer le long tuyau au raccord en Y et serrer les racco...

Страница 30: ...tement RACCORDEMENT DU CONDUIT D ÉVACUATION Raccorder le conduit d évacuation à la bouche d évacuation 1 À l aide d une bride de serrage de 4 102 mm relier le conduit d évacuation à la bouche d évacuation de la sécheuse Si on utilise le conduit d évacuation existant s assurer qu il est propre Le conduit d évacuation de la sécheuse doit être fixé par dessus la bouche d évacuation de la sécheuse et ...

Страница 31: ...umulation de tartre peut obstruer différentes parties du circuit d eau ce qui réduira la performance du produit Une accumulation excessive de tartre peut entraîner la nécessité de remplacer ou de réparer certains composants Modèles électriques q Brancher sur une prise reliée à la terre Modèles à gaz q S assurer que l alimentation en gaz est ouverte q Vérifier qu il n y a pas de fuites DÉPANNAGE Vo...

Страница 32: ...W10372564B W10372565B SP 2011 All rights reserved Tous droits réservés 6 11 Printed in U S A Imprimé aux É U ...

Отзывы: