6
24 in.
2
(155 cm
2
)
48 in.
2
(310 cm
2
)
1"
(25 mm)
1"
(25 mm)
5"
(102 mm)
3"
(76 mm)
34" recommended
(864 mm)
18" min.
(457 mm)
3"
(76 mm)
Back view:
INSTALL LEvELINg LEgS
1.
Prepare dryer for leveling legs
To avoid damaging floor, use a large flat piece of cardboard
from dryer carton; place under entire back edge of dryer.
Firmly grasp dryer body (not console panel) and gently lay
dryer down on cardboard.
6
1
/
2
"
(165 mm)
30
1
/
2
"
(775 mm)
6
1
/
4
"
(159 mm)
6
1
/
4
"
(159 mm)
14
1
/
2
"
(368 mm)
1
1
/
2
"
(36 mm)
4
1
/
4
"
(108 mm)
Mobile home - Additional installation requirements:
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR,
Part 3280 (formerly the Federal Standard for Mobile home
construction and Safety, Title 24, HUD Part 280) or Standard
Mobile Homes, CAN/CSA-Z240 MH.
Mobile home installations require:
All dryers:
Metal exhaust system hardware, available for purchase
■
from your dealer. For further information, see “Assistance
or Service” section in your “Use and Care Guide”.
Special provisions must be made in mobile homes
■
to introduce outside air into dryer. Openings (such
as a nearby window) should be at least twice as large
as dryer exhaust opening.
For gas dryers mobile home installations:
Mobile Home Installation Hold-down Kit Part Number
■
346764 is available to order. For further information, see
“Assistance or Service” section in your “Use and Care
Guide”.
NOTE:
Most installations require a minimum 5" (102 mm)
clearance behind the dryer for the exhaust vent with elbow.
See “Venting Requirements”.
Installation spacing for recessed area or closet
installation
The dimensions shown below are for the recommended spacing for
this dryer.
Additional spacing should be considered for ease of
■
installation and servicing.
Additional clearances might be required for wall, door, and
■
floor moldings, and dryer venting.
Additional spacing of 1" (25 mm) on all sides of the dryer is
■
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings
■
in the top and bottom of the door are required. Louvered doors
with equivalent ventilation openings are acceptable.Companion
appliance spacing should also be considered.
Recommended installation spacing:
Содержание Vantage WGD7990X
Страница 2: ...2 DRYER SAFETY ...
Страница 3: ...3 When discarding or storing your old clothes dryer remove the door ...
Страница 16: ...16 Sécurité de la sécheuse ...
Страница 17: ...17 Pour mettre l ancienne sécheuse au rebut ou pour la remiser enlever la porte ...
Страница 32: ...W10372564B W10372565B SP 2011 All rights reserved Tous droits réservés 6 11 Printed in U S A Imprimé aux É U ...