360471

Dimensions and Installation Information (in inches) 

Exhaust Options: 

3-way via rear, right, and bottom.

Circuit Requirements: 

An individual, properly grounded 

branch circuit, protected by a 30-amp circuit breaker or 
a time-delay fuse, is required.

Note: 

Dryer wall outlet must be located within 36” 

of service cord entry and accessible when dryer is 
mounted in position.

Installation Information: 

For complete information, see 

installation instructions packed with your dryer.

SIDE VIEW

28-1/2

48-1/2

4-3/4

Optional

Vent Knockout

Door Open

90°

4-3/8

REAR VIEW

27

5

2-1/4

36

Under

Counter

36

3/16" 

Gas Pipe Connection

Electric 

Connection

13-9/16

Gas Dryer Rating

120V

60Hz, 6A

DSXH47GG 

GE

®

 5.8 Cu. Ft. Extra-Large Capacity Frontload Gas Dryer

 

Содержание DSXH47GG

Страница 1: ...protected by a 30 amp circuit breaker or a time delay fuse is required Note Dryer wall outlet must be located within 36 of service cord entry and accessible when dryer is mounted in position Installation Information For complete information see installation instructions packed with your dryer SIDE VIEW 28 1 2 48 1 2 4 3 4 Optional Vent Knockout Door Open 90 4 3 8 REAR VIEW 27 5 2 1 4 36 Under Coun...

Страница 2: ... otherwise ventilated and must contain a minimum of 60 sq in of open area equally distributed If this closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed No other fuel burning appliance shall be installed in the same closet with a gas dryer Bathroom or Bedroom Installation The dryer MUST be exhausted to the outdoors The installation ...

Страница 3: ... of 4 rigid aluminum or galvanized duct which can be tolerated is shown in the table A turn of 45 or less may be ignored Two 45 turns within the duct length should be treated as a 90 elbow A turn over 45 should be treated as a 90 elbow Dryers must be exhausted to the outside Caution For personal safety do not terminate exhaust into a chimney under any enclosed house floor crawl space or into an at...

Страница 4: ...our Temperature Options Provides the right temperature for the right drying results On Off End Of Cycle Signal Can be turned on so you can hear it from another room or turned off when you do not want to disturb others Four Auto Dry Cycles A variety of fast and flexible options for drying clothes Sensor Dry Continually monitors moisture levels to help clothes look better longer Interior Dryer Light...

Отзывы: