Run Diagnostic Mode and verify
•
fault code
While in Diagnostic Mode - Start Clean
•
cycle, to verify that door does latch.
Unplug range or disconnect power
•
If door did not latch - check for
•
contunity:
Upper Oven - P7-4 to P7-2
Lower Oven - P7-4 to P7-3
(Latch Switches)
If no contunity - check for
•
500-3000Ω resistance at P5-6 to
P6-3 or P5-5 to P6-3 (Latch Motors)
If resistance check fails - replace
•
Latch motor.
If resistance check is good, check door
•
(slot) and latching rod alignment. If door
alignment is good - Replace Door Latch
Switch
Run Diagnostic Mode and verify fault
•
code
Unplug range or disconnect power
•
Replace Control
•
Check House power supply and verify
•
240VAC is available at the wall outlet.
MRC II Fault Code Procedure (continued)
F5 E1 (Door Latch System)
All F6 E* (Control Communication)
All F9 Fault Codes (House Miswired)