27
1-
All F3 E* (Sensor)
Run Diagnostic Mode and verify
•
fault code
Unplug range or disconnect power.
•
Check Sensor for 1000-1200 Ω at
•
CON3-9 to CON3-10
Check Sensor for short to ground
•
If checks are not correct -
•
Replace Sensor
LCC Fault Code Procedure (continued)
F5 E0 F5 E2 (Door Switch)
Run Diagnostic Mode and
•
verify fault code
• Unplug range or disconnect
power.
Check door switch for
•
continuity with door open and
door closed at CON3-4 to CON3-3
Door Open -Infinite Resistance
Door Closed - 0 resistance
If checks are not correct -
•
Replace Door Switch
Run Diagnostic Mode and verify
•
fault code
Unplug range or disconnect power.
•
Replace Control
•
F2 Fault Code (Stuck Key on Control)
Run Diagnostic Mode and verify
•
fault code
Unplug range or disconnect power.
•
Replace Control
All F1 E* Codes (Control)