14
INSTALLATION
Downward safety distance
To guarantee correct ventilation, it is necessary to maintain a minimum distance
between
the appliance and an oven, an intermediate shelf or a drawer.
The minimum distance between the lower edge of the hob and
- the upper edge of an oven must be 15mm
- the upper edge of an intermediate shelf must be 15mm
- the bottom of a drawer must be 75mm
Safety distance from the niche covering
If a covering is applied to the niche, a minimum distance must be observed between
the worktop niche and the covering as high temperatures can damage or modify the
materials.
If the covering is made of flammable material (e.g. wood), the minimum distance
between the worktop and covering must be 50mm
If the covering is made of non-flammable material (e.g. metal, natural stone, ceramic
tiles), the minimum distance between the worktop and covering notches must be
50mm less the thickness of the covering.
Example: covering thickness 15mm
50mm - 15mm = minimum distance 35mm
Electrical connection
The appliance can only be connected to the electrical network by a qualified
electrician who is fully familiar with the general specific regulations of the local
electricity company in force and who operates in compliance with the same.
Absorbed power
see data plate
Connection and protection
The necessary connection data is indicated on the plate and must correspond to that
of the mains.
Determine the various connection possibilities from the relevant diagram.
Differential switch (circuit breaker)
For greater safety, it is advisable to include a circuit breaker with 30mA
disconnection current
Separation devices
The device must be deactivated by means of disconnecting devices for each pole.
(When the device is switched off, the contact opening
must be
at least 3mm). The
disconnecting devices are overcurrent protections and protection switches.
Disconnect the appliance from the power supply
To disconnect the electrical circuit from the mains, after installation proceed as follows:
-
Fuses:
completely remove the fuses of the threaded caps or
-Automatic protections:
press the control button (red) until the central button (black) or