5
2. For added personal safety, use a separate grounding
wire. Remove terminal box cover. Feed grounding wire
through the hole in the terminal box where the power
cord enters. Connect the separate grounding wire to
the green, grounding screw inside the terminal box.
Connect the other end of the separate grounding wire
to a grounded, metal cold water pipe*. (See Figure 5.)
3. Replace terminal box cover.
Do Not connect to electrical supply until appliance is
permanently grounded.
Do Not ground to a gas supply pipe or hot water pipe.
*Grounded, cold water pipe must have metal continuity to
electrical ground and not be interrupted by plastic, rubber
or other insulating connectors such as hoses, fittings,
washers or gaskets (including water meter or pump).
Any insulating electrical connector should be jumped,
as shown, with a length of No. 4 copper wire securely
clamped to bare metal at both ends.
If power cord cannot be used...
When local codes do not permit use of a power cord with an
undercounter dishwasher, the power cord must be removed
and dishwasher wired directly. IF THE POWER SUPPLY
CORD IS REMOVED, THE DISHWASHER MUST BE
CONNECTED WITH COPPER WIRE ONLY.
1. Disconnect power.
2. Remove terminal box cover.
3369671-C
(continued)
Figure 6
4. Disconnect the stain relief (behind the terminal box) from
the dishwasher frame.
5. Remove power cord, strain relief and terminal box
bushing.
6. See “A. Direct wire method,” pages 3 and 4, for
further instructions.
Water requirements
The hot water line to the dishwasher must provide between
15-120 PSI water pressure. The hot water heater should
be set to deliver 140°F water temperature to the dish-
washer for best results.
Use
3
⁄
8
" O.D. copper tubing or
1
⁄
2
" plastic tubing minimum
inlet line. Dishwasher inlet valve has
3
⁄
8
" internal pipe
threads.
Drain requirements
The drain hose MUST have a high drain loop 20" minimum
ABOVE FLOOR to prevent backflow or water siphoning out
of dishwasher during operation.
NOTE: An air gap MUST BE USED in the high drain loop if
the drain hose is connected to house plumbing lower than
20" above the floor.
20" (51 cm) minimum to floor
1. Have a 3-prong, grounding-type, wall receptacle avail-
able or installed by a qualified electrician on the rear or
side wall of a cabinet next to the dishwasher opening.
(See Figure 1, Page 2.)
Terminal box
Terminal
box cover
Cover
screw
Green
grounding
screw
Bumps on
grounding
clamp must
contact pipe.
Grounding
clamp must
be tight
on pipe.
No. 4 wire
Meter
Clamps
Metal cold
water pipe
Pipe must be
free of paint, dirt,
grease.
Figure 5
Grounding
wire
Terminal Box
Terminal
Box Cover
U.L.-
listed
strain
relief
Dishwasher
Wiring
Grounding
Wire
Power
Supply
Cord
Bushing
Cover
Screw
3. Remove twist-on wire connectors from the power cord
wires and grounding wires. (See Figure 6.)