background image

15

Description of Equipment: Shower Drain System       

Manufacturer’s Declaration

We hereby declare, under our sole responsibility,
that the above equipment complies with the
provisions of the following EC Directives.

Electromagnetic Compatibility Directive
89/336/EEC, amended by 92/31/EEC and
93/68/EEC on the approximation of the laws of the
Member States relating to electromagnetic
compatibility.  

Low Voltage Directive 73/23/EEC amended by
93/68/EEC on the harmonization of the laws of the
Member States relating to electrical equipment
designed for use within certain voltage limits.

CE mark affixed: 03/06/05                                      

Basis on which conformity is declared

The above equipment complies with the protection
requirements of the EMC Directive and the
principal elements of the safety objectives of the
Low Voltage Directive.

Standards applied 

EN 60335-1:2002/A11:2004 Safety of household
and similar electrical appliances

EN 60335-2-41:2003 Particular requirements for
pumps

EN 55014-1:2000 Electromagnetic compatibility.
Requirements for household appliances, electric
tools and similar apparatus. Emission

EN 55014-2:1997 Electromagnetic compatibility.
Requirements for household appliances, electric
tools and similar apparatus. Immunity. 

Signed

David Cresswell

Engineering Director

Munster Simms Engineering Ltd.
277-279 Old Belfast Road
Bangor, Co. Down, BT19 1LT

EU Declaration of Conformity

Содержание BP1558B

Страница 1: ...Automatic Pumped Shower Drainage Systems Model Number BP1558B Shower Tray Kit Model Number BP1578 Wet Floor Kit Installation guidelines for This booklet should be read before installation...

Страница 2: ...this Whale Shower Drain Pump Kit product Since 1995 Whale has been the leading manufacturer of pump kits for use with shallow shower trays and wet floors These kits have the reputation of working rel...

Страница 3: ...rmer pump flow switch and filter must be accessible after installation The shower floor must have a fall of 25 mm in 1 m Plumbing installation must comply to latest WRAS regulations The electrical wir...

Страница 4: ...1 11 Wiring Diagram 9 1 12 Shower Zone Area 10 1 13 Transformer Mounting 10 1 14 Transformer Setting 11 1 15 Pump Head Cross Section 12 Illustrations Pump Installation and Plumbing 5 6 7 Plumbing of W...

Страница 5: ...maximum height of 500 mm Remove the pump cover and place the pump in the back plate and position where the pump is to be fixed Mark the pump mounting points through the 4 slots in the back plate See...

Страница 6: ...er shower installations pipework from the gulley into the pump must be 22 mm to give a flow rate of 12 litres min Note For mixer shower installation an additional flow switch and fittings are required...

Страница 7: ...ng the hand tool provided to tighten the locking flange fit the gulley cover into the sockets and push down to secure Top Tip Leave the hand tool in place to prevent building debris grout etc falling...

Страница 8: ...pipe McAlpine offer waste adaptors with 22 mm inlets At time of print A10V and V33T offer a solution Use with a Macerator Pump 4 3 Where the situation demands or if the pipe run is greater than that...

Страница 9: ...low switch connections to the transformer bell wire are not polarity sensitive and can be made using the electrical connector block supplied 6 4 The transformer 24v RED and BLACK cable supply to the p...

Страница 10: ...and secure to a flat surface 7 3 Connect transformer to 240V AC supply via a 5 amp fused spur Test Button 8 1 The transformer has a built in Test Button on the face of the transformer above the cable...

Страница 11: ...tions Setting 2 Mixer Electric M E Select your type of installation M Default Setting for Mixer Valve E Electric shower setting Setting 3 Off Delay 10 30 90 180 seconds Adjust the time that the pump w...

Страница 12: ...damage to the pump 9 4 An additional advantage of the three non return valves in the pump head is that no smells can be passed back from the waste stack into the shower area 10 1 Before setting up the...

Страница 13: ...e cables 5 m 10 amp rating Pump control cable 2 core 5 m Start delay short or long Shower type selector Off Delay of 10 30 90 180 seconds 5 amp Slow blow fuse Whale s policy is one of continuous impro...

Страница 14: ...kmanship If the system proves faulty return it to your distributor with proof of purchase and purchase date The manufacturer cannot be held responsible for claims arising from incorrect installation u...

Страница 15: ...k affixed 03 06 05 Basis on which conformity is declared The above equipment complies with the protection requirements of the EMC Directive and the principal elements of the safety objectives of the L...

Страница 16: ...16 Transformer 755 199 Pump SDS021T...

Страница 17: ...17 50mm Gulley 755 140 Pump Cover...

Страница 18: ...22 mm 16 mm 38 mm 122 mm Vinyl Floor Gulley AK1610 Spares for BP1558B and BP1578 Pump Only SDS021T Flow Switch AK1568 Diaphragm Service Kit AK1550 Mixer Valve Conversion Kit AK1570 Transformer 755 19...

Страница 19: ...emove the transformer and check the fuse fitted on the base Replace it if it has blown 5 0A T Does pump start Note If fuse blows persistently check the pump cable to make sure it is not damaged or sho...

Страница 20: ...hale Old Belfast Road Bangor BT19 1LT N Ireland UK Technical Helpline 0845 0694 253 whalepumps com info whalepumps com tel 44 0 28 9127 0531 fax 44 0 28 9146 6421 Ref No 182 78 0807 v1 Contact Details...