Pro-Guard & Uni-Guard Installation Manual
28
Key ID E: Load Default Settings
(Default value: 0; valid range: 0-1)
Value Action
0 Initial
state.
1
Load default settings.
Input 1 will load default settings. See Default Parameters Table.
Key ID P: Password Change
(Default value: 689; valid range: 0-999)
You can input customer-defined passwords with this entry. Press [CON] button after inputting
to activate the new password.
Note: Please SAFEGUARD the new password if you have changed from the default.
Once the new password is activated, the system will no longer recognize the 689
default password.
Key ID EX: Exit
Press [EX] to return to the alarm counter display status.
Key ID SA: Save
This button will save all current parameters to flash ROM and are saved, even after power
shutdown. When the system is rebooted, it will load all previously saved parameters from
flash ROM.
•
Press [SA] – panel displays as per Figure 8.
•
Input 1
•
Press [CON] to accept the current parameters.
Figure 8.
***