Pro-Guard & Uni-Guard Installation Manual
19
IR Control Keyboard Function Description & Default Parameters Table
Key ID
Button
Parameters Description
Default Value
Valid Range
A
GN
Gain Adjustment
1
0, 1
B
SYN
Sync Adjustment
1
0 to 250
C
RE
Receiving Window Delay
8
0 to 15
H1
Minimum signal adjustment for
antenna Channel 1
H2
MIN
Minimum signal adjustment for
antenna Channel 2
40
0 to 999
(Practical
range 0-200)
D
NSE
Noise Display (2 channels)
0
0 to 2
F
TX OFF
Turn off transmitter
1
0 to 1
E
DFT
Return to default settings
0
0 to 1
P
PC
Password change
689 (see note)
0 to 999
G
ARM OFF
Turn off alarm sound
1
0 to 1
L
ARM RST
Alarm count reset
0
0 to 1
S
SA
Save the parameters to Flash ROM
0
0-1
CON
Confirm the parameters input
NA
NA
EX
Exit
NA
NA
Note: Default password is 689. After changing, the system will use the new password
as default. The new password will remain saved at power off.
PC
PSW
1
2
3
4
5
6
7
8
9
0
CON
TX
OFF
MIN1
DFT
MIN2
GN
SYN
ARM
OFF
RE
NSE
ARM
RST
SA
EX