WD-59CTS & WD-66CTS
Rev. (202210)
Technical specifications
53
* When the machine is steam-heated.
** in accordance with EN 60 335-2-58, §ZAA.2.8 with instruments that satisfy
class 1.
Measurements of the sound pressure level on site are performed in three places
20 cm from the edges of the front at a height of 1.55 m using a microphone.
When measuring sound power level, create an imaginary measurement area
consisting of five sides at a distance of 1 m from all edges of the machine.
* Other voltages on request.
* Other voltages on request
CAPACITY AND OPERATING DATA
WD-59CTS
WD-66CTS
Capacity (trays/min.)
25
25
Capacity (cutlery/min.)
75
75
Max. tray size (mm)
530x530
530x530
Cold water consumption, final rinse (litres/min.)
5
5
Steam consumption at 150–250 kPa (kg/h) *
50
55
Steam consumption at 50–140 kPa (kg/h) *
50
55
Surface temperature at a room temperature of 20°C (°C)
35
35
Sound pressure level, LPA (dB(A)) **
63 **
63 **
Sound power level, LWA (dB(A)) **
83 **
83 **
CONNECTION, ELECTRICALLY HEATED MACHINE
WD-59CTS
WD-66CTS
Total connected load (kW)
49.7
50.4
Main fuse 400-415 V 3N~ (A) *
80
100
Max. connection area 400-415V 3N~ (L1-L3, N, PE) (TN-S)
Cu (mm²)
70
70
Maximum short-circuit current Icu (kA)
10
10
CONNECTION, STEAM-HEATED MACHINE
WD-59CTS
WD-66CTS
Total connected load (kW)
7.7
8.4
Main fuse 400-415 V 3N~ (A) *
25
35
Max. connection area 400-415V 3N~ (L1-L3, N, PE) (TN-S)
Cu (mm²)
35
35
Maximum short-circuit current Icu (kA)
10
10
Steam connection (internal thread)
R1"
R1"
Condensing water connection (internal thread)
R¾"
R¾"