WD-59CTS & WD-66CTS
Rev. (202210)
Installation instructions
22
When installing a connection from the ceiling, the pipes must be fed from above
down through the cable duct behind the cover plate (A) next to the electrical
cabinet. Remove the cover plate, break away the perforated plate on top of the
cover plate and debur any sharp edges.
Connection from ceiling
A = Cover plate
3.6.5
Ventilation
The machine’s heat load for the room is stipulated in TECHNICAL
SPECIFICATIONS.
The machine has a heat recovery unit connected to an exhaust fan to reduce the
amount of steam released. Extractor fans for extracting steam can be installed
above the infeed and outfeed openings, as well as above the area of the machine
where steam is emitted from the condensing fan.
3.6.6
Steam (optional)
A shut-off cock must be installed on the incoming pipe (6). The required steam
pressure can be found in the TECHNICAL SPECIFICATIONS.
The connection is fitted with a filter. When connecting a pipe from the ceiling, it is
taken into the same area as the water pipes behind the cover plate next to the
electrical cabinet.
Condensing water
A condensation connection (5) is only provided on steam-heated machines. The
pipe is connected to the system’s steam boiler.
66CT_T_10
A