WESTLAB
SMART MICRO
CENTRIFUGE

USER MANUAL

CODE  663-958

C

1. INTRODUCTION

This Westlab Smart Micro Centrifuge offers versatility, 

simplicity, safety, and ease of usage in a single package. 

This product has been designed after studying 

centrifuges and its usage in numerous scenarios of the 

lab environment. This Micro centrifuge is specially 

suitable for microfiltration, cell separations, 

centrifugal tube sedimentation, and spin down 

applications. Please read this manual thoroughly 

before operating the centrifuge.

3. FEATURES

• BLDC motor for maintenance free long life

• 8 Position closed micro tube rotor

• Closed rotor leads to lesser friction, reducing noise

& heat generation

• Digital display

• Highly efficient & accurate

• Electronic safety brake on lid opening for user safety

• Quick start & stop for short spin

• Smooth and quiet running

• Tiny footprint: It can squeeze easily on to a

crowded counter top

• Interchangeable PCR rotor & adaptor

• Low voltage instrument with external power adaptor

• Speed and time setting function

• Digital timer programming function

• Variable speed settings RPM Increments At 100 rpm

• Imbalance cut off for safety

2. INTENDED USE

This Westlab Smart Micro Centrifuge is used in various 

laboratories to separate particles from suspension or 

even macromolecules from solutions according to their 

density. The different biological substances that are 

usually separated by centrifugation are microbial cells, 

organelles, proteins, DNA, and RNA.

Note:

 This user guide is intended to assist with the operation 

and care of the unit only and not for its repair. The customer 

should not attempt to service or repair the unit. If repairs are 

required, please contact the supplier.

Содержание 663-958C

Страница 1: ...nical Specifications 2 5 Standard Accessories 2 6 Safety Precautions 2 7 Installation 3 8 Standard Part Listing 4 9 Rotor Balancing 4 10 Interchageable Rotor 5 11 Changing the Rotor 5 12 Opening Centr...

Страница 2: ...e on lid opening for user safety Quick start stop for short spin Smooth and quiet running Tiny footprint It can squeeze easily on to a crowded counter top Interchangeable PCR rotor adaptor Low voltage...

Страница 3: ...4 C to 45 C Main supply voltage fluctuations not to exceed 10 of the nominal voltage Position at least 20 cm from walls 20 cm from ceiling and 20 cm between other products Make sure to always install...

Страница 4: ...ied micro centrifuge tubes made from plastic and designed to withstand centrifugal forces of at least 2000 g Do not operate the centrifuge without the rotor being properly attached to the shaft Re che...

Страница 5: ...e serious damage to the centrifuge 8 STANDARD PARTS LISTING ON OFF SWITCH NON SLIP RUBBER BASE POWER SOCKET PROTECTIVE LID ROTOR SAFETY SWITCH DISPLAY RELEASE BUTTON SPEED KNOB x 100RPM Min 60 TIMER K...

Страница 6: ...is located at the bottom of the rotor on the marked side To remove the rotor turn counter clockwise to loosen the screw and then gently pull the rotor up vertically Insert the new rotor from the top...

Страница 7: ...ter clockwise direction Trying to open the centrifuge lid by pulling the Lid Release button up is the wrong method of opening the lid Pulling the Lid Release button up will break the button or damage...

Страница 8: ...id accidents and damage to the centrifuge 4 Close the lid flip ON the front switch to start centrifugation 5 Once the centrifugation is completed turn the front switch to Off to gradually stop the rot...

Страница 9: ...nd rotor the actual RCF value will vary One can refer to the table mentioned in the section 7 to get the actual RCF of different rotors at certain given speed values 8 The unit is equipped with a 0 25...

Страница 10: ...ge to the centrifuge This centrifuge has an unique patented feature to protect the centrifuge its user the surroundings against such as accidental run When such an event occurs the sensor build inside...

Страница 11: ...us materials occur within the rotor or rotor chamber the unit should be disinfected This should be performed by qualified personnel with proper protective equipment Do not use any cleaning or decontam...

Страница 12: ...turned for service should be sent with postage prepaid in the original packaging or other suitable packaging padded to avoid damage We will not be responsible for damage incurred by improper packaging...

Отзывы: