44
WHL-012 REV. 12.17.14
Figure 33
– CH Set-Point Screen
Factory CH Set-Point is 180
o
F (82
o
C). CH Set-Point range is 86
– 180
o
F (30
– 82
o
C).
Turn the dial
counterclockwise to lower and clockwise to raise the current CH set-point. After changing the temperature, press the
button to save the setting.
G. STORAGE MODE
Storage Mode indicates that the appliance is heating stored water in the internal storage tank. When Storage Mode is operating the
display appears as follows.
Figure 34
– Storage Mode Screen
H. STATUS DISPLAY MODE
Status Display Mode will activate when the
button is pressed and held for five seconds when the display panel is powered ON.
Figure 35
– Status Mode Screens
Turn the dial
counterclockwise and clockwise to scroll through the displayed parameters. To view parameter details, press the
button at the appropriate screen. Press the
or
buttons to leave the parameter.
Press the
button again to return to Operation Mode.
To turn on Lock Mode, press the
button at the d:Lc parameter. Turn the dial
counterclockwise or clockwise to scroll On or Off.
Press the
button to save the selection and return to the parameters.