background image

6 | Westinghouse Outdoor Power Equipment, LLC

SPECIFICATIONS

Model Name:

iGen1000s

Battery Cell 

Chemistry:

Lithium Ion (Li-ion) NMC          

Capacity:

1008Wh (50.4V, 20Ah)

Running Watts:

1500W

Peak Watts:

3000W

Total Power:

1800W (1500AC / 300DC)

AC Output Voltage: 120V
Frequency: 

50Hz or 60Hz

Sine Waves Type: Pure
Life Cycle:

800 Cycles to 60% Capacity

Charge Time:

With AC charger:

•  0-80% charge 2 hours
•  0-100% charge 3 hours

Charging 

Temperature 

Range:

32° – 113°F (0° – 45°C)

Operational  

Temperature 

Range: 

-4° – 113°F (-20° – 45°C) 

Series Capable:

Yes

Warranty:

2 Years

Certifications:

FCC, RoHS, UN38.3, BC

WHAT’S IN THE BOX? 

User Manual 

1.5m Car Charge Cable

(Input)

Part# PS100003

1.5m AC Cable

(Input)

Part# PS100001

iGen1000s

3.5m Solar Charge Cable

(MC4 to XT60 Input)

Part# PS100002

REGISTERING YOUR PRODUCT

Registering your product Online at 

wpowereq.com/register

. To register you will need the serial 

number on the Power Station which is located on the bottom of the unit.

INTENDED USE

The Westinghouse iGen1000s Power 

Station is intended as a power supply for 

electronic devices with a maximum power 

consumption of 1500W. Our product is 

not suitable to be used with equipment 

that relates to one‘s own personal 

safety and relies heavily on electricity, 

such as medical devices, equipment 

for nuclear facilities, the manufacture 

of air and spacecraft, etc. We therefore 

assume no liability for accidents involving 

personal safety, fires, or machine failures 

caused by using our product with the 

aforementioned devices.

Содержание iGen1000s

Страница 1: ...en1000s Portable Power Station 1500 Running Watts 3000 Peak Watts USER MANUAL DO NOT RETURN THIS PRODUCT TO THE STORE If you have questions or need assistance please call customer service at 855 944 3571 ...

Страница 2: ...UCT 6 CONTROLS AND OUTLETS 7 DC OVERLOAD PROTECTION 8 AC OVERLOAD PROTECTION 8 LCD DISPLA Y 9 OPERATION 10 HOW TO POWER DC DEVICES 10 COLD WEATHER USE 10 POWER STATION OUTPUT CAPACITY 10 SERIES OPERATION 11 UPS OPERATION 11 AC CHARGING 12 VEHICLE CHARGING 12 SOLAR CHARGING 13 SOLAR SERIAL CHARGING 13 SOLAR SERIAL AND PARALLEL CHARGING 14 CLEANING 15 TRANSPORTATION AND STORAGE 15 RECYCLING 15 ...

Страница 3: ...Westinghouse Outdoor Power Equipment LLC DANGER Read this manual before using this product Failure to follow the instructions and safety precautions in this manual can result in damage to the product or personal property or serious injury or death DO NOT use the product with incompatible components or alter the product in any way SAVE THESE INSTRUCTIONS The following terms are used in this documen...

Страница 4: ... users are advised to attempt to correct the interference by one or more of the following measures Re adjusting or placing the receiving antenna Increase the distance between the device and the receiver SAFETY WARNING Improper use may result in fire property damage or personal injury Make sure to use the product according to the following safety rules and guidelines WARNING Do not expose the iGen1...

Страница 5: ...d dry environment DO NOT use and store in dusty or wet environment Check the unit prior to every use DO NOT use the unit if it is damaged or broken DO NOT use the unit if the power cord is damaged or broken Keep the unit away from children DO NOT let children use the Power Station Keep this product away from pets DO NOT use or store the unit in an area or environment with high temperature Should f...

Страница 6: ...1 5m AC Cable Input Part PS100001 iGen1000s 3 5m Solar Charge Cable MC4 to XT60 Input Part PS100002 REGISTERING YOUR PRODUCT Registering your product Online at wpowereq com register To register you will need the serial number on the Power Station which is located on the bottom of the unit INTENDED USE The Westinghouse iGen1000s Power Station is intended as a power supply for electronic devices wit...

Страница 7: ...ill illuminate when in use or turned ON Turning the DC ON OFF button to the ON position will keep the DC power ON for 24 hours to charge low power devices such as earphones which will not automatically turn DC power ON 5 Fast charge USB A output ports The USB A Output indicator light will illuminate when a USB A port is in use or turned ON Fast charge enabled devices can be charged at a maximum sp...

Страница 8: ... cord into the port and connect the three pin plug into a 120V 60Hz AC power source 13 Overload protection button If the input current exceeds 20A during charging the AC charging port will trigger the overload protection See Notification Icons section When the overload indicator has turned off push the Overload Protection button to reset and continue charging DC OVERLOAD PROTECTION When any DC por...

Страница 9: ... indicator is flashing contact customer support h Current output power in Watts b Battery percentage of power remaining i Overload warning d High temperature indicator Allow the unit to cool before use j Indicates the usage status of each port e Low temperature indicator Move the unit to a warmer location k Notification icons f Fan indicator Shows automatic cooling fan is in operation ...

Страница 10: ...f the device 4 When finished push the DC ON OFF button to turn off DC power NOTICE If the total output exceeds the wattage output of the DC outlet the power station will automatically shut off Ensure the power consumption is less than what the ports are rated before connecting them to the Power Station COLD WEATHER USE Cold temperatures below freezing can affect the unit s battery capacity due to ...

Страница 11: ...ts ON then push the AC ON OFF button on both units to turn AC power ON 4 Connect devices to the AC outlets on the Active unit and enjoy twice the battery life Note Do not connect any electrical devices into the Master unit while in series operation UPS OPERATION The iGen1000s can be used as a temporary Uninterruptible Power Supply UPS to provide continuous power in case of a power outage You can u...

Страница 12: ... CHARGING WARNING Do not charge the Power Station immediately after it is fully discharged For safety wait 2 to 3 hours for the product to cool down before charging If you attempt to charge iGen1000s immediately after a full discharge the iGen1000s will display as an overheating protection reminder Connect the unit to a 120V 60Hz power supply as shown 500W Max Charge Input 3 0 Hours 0 80 charge in...

Страница 13: ...he third party solar panels including during the warranty period Connect a solar panel not included equipped with a MC4 connection to the supplied MC4 to XT60 conversion cable Plug the XT60 cable into the unit as shown Cable included with iGen1000s MC4 to TX60 INPUT PORT SOLAR PANEL SOLAR Panel MC4 Adapter Cable XT60 Connector iGen1000s Charging Port SOLAR SERIAL CHARGING Connect 1 to 3 solar pane...

Страница 14: ... of three solar panels connected in series then connect the two sets of solar panels in parallel parallel cable sold separately Connect the panels to the MC4 to XT60 conversion cable Plug the XT60 cable into the unit as shown XT60 Connector iGen1000s Charging Port Users have to buy the solar panels and other parallel connection accessories seperately Solar MC4 parallel connection cable iGen1000s S...

Страница 15: ...ment DO NOT place the product where it may contact water or high humidity Make sure no small metal objects can fall on or around the product while in storage Never transport a product with a battery power level higher than 30 Never store the product in environments below 4 F 20 C or above 113 F 45 C RECYCLING Dispose of the unit in hazardous material specific recycling locations only after a compl...

Страница 16: ...n RECHARGING TIME Exclamation and Low temperature icons flash together Place the unit in a warmer location and wait for it to return to the charging temperature range before recharging Low Temperature Discharge protection Exclamation and Low Temperature icons flash together Place the unit in a warmer location and wait for it to return to the charging temperature range before recharging Overload Re...

Страница 17: ...gh temperature icons flash together Let the unit cool down Inverter Low Temperature Protection The AC and Low Temperature icons flash together Place the unit in a warmer location and wait for it to return to operational temperature range Fan Blockage AC and Fan icon flashes Turn off the unit and carefully clean and vacuum around vents on both sides Turn power ON If icon keeps flashing contact West...

Страница 18: ...Drive Columbus OH 43228 WestinghouseOutdoorPower com WESTINGHOUSE and INNOVATION YOU CAN BE SURE OF are trademarks of Westinghouse Electric Corporation Used under license by Westinghouse Outdoor Power Equipment All Rights Reserved PC10000 Rev 01 ...

Отзывы: