8 | Westinghouse Outdoor Power Equipment, LLC
7. AC ON/OFF button:
The AC power needs
to be turned ON manually. Push and hold to
turn AC power ON/OFF. The indicator light
will illuminate when main power is ON. Turn
OFF when AC power is not in use to conserve
battery life. Unplug all power cord from the AC
ports when not in use. If the AC power is not
used for more than 12 hours, the unit will turn
off automatically. For 50Hz operation, push
and hold the AC ON/OFF for 15 seconds to
switch between 50 and 60Hz. Confirm 50 or
60Hz on LCD display before use.
8. Ventilation fans:
The fans prevent the unit
from overheating. Never block or obstruct the
ventilation vents.
9. 6 AC outlets:
Used to charge devices that
require 120V AC such as laptops, TVs, mini
refrigerators, vacuums, etc.
10. Car outlet:
Used to charge devices that
require a car outlet to be charged, such as
drone batteries. The Car Outlet indicator
light will illuminate when the car outlet is in
use.
11. Solar / Car charging input:
Supports a
maximum of three 110W solar panels to be
connected in series. Do not put more than
two solar panels in parallel connection.
iGen1000s has a limit input of 400W.
Supports car charge with a maximum input
of 10A.
12. AC charging input:
Plug in the supplied AC
cord into the port and connect the three-pin
plug into a 120V/60Hz AC power source.
13. Overload protection button:
If the input
current exceeds 20A during charging, the
AC charging port will trigger the overload
protection (See Notification Icons section).
When the overload indicator has turned off,
push the Overload Protection button to reset
and continue charging.
DC OVERLOAD PROTECTION
When any DC port is powering devices that
exceed maximum current limit, or the output
power of the AC jack exceeds the maximum
AC power output, the overload icon will be
shown on the display and the corresponding
interface indicator will flash simultaneously for
15 seconds. The output of the affected port
will be automatically turned off. Other ports will
continue to operate.
Remove the devices connected to the DC ports.
Make sure the Power Station can supply enough
continuous (running) and peak (starting) watts
for the items you will power at the same time
before reconnecting devices.
AC OVERLOAD PROTECTION
When the power output exceeds the battery
maximum power output, the overload icon will
be shown on the display and the corresponding
port indicator will flash simultaneously for 15
seconds. The unit will automatically shut down.
After an overload occurs, remove the connected
devices. Make sure the Power Station can
supply enough continuous (running) and peak
(starting) watts for the items you will power at
the same time before reconnecting devices.