The WESTFIRE WF UNIQ 23, stove is lined with heat deflection panels and baffles, these panels are designed to en-
sure the maximum efficiency and are an integral part of the clean burn process of the stove. These baffles should 
not be removed other than for cleaning the stove. Any defective panels should be replaced.

top or rear flue connection
The WESTFIRE UNIQ 23 stove is factory set up with a top flue outlet, this can be altered to a rear connection by 
unbolting the top collar, rear cover plate and exchanging collar and plate. Care should be taken to ensure an 
airtight fit when refitting collar and plate. A decorative cover plate is included with every stove to cover the hole 
in the convection top plate. This collar allows connection to either a masonry chimney or a prefabricated factory 
made insulated metal chimney.

Commissioning and handover
Ensure at parts are fitted in accordance with the instructions in this booklet and comply with national regulations.
On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out, a small 
fire may be lit to check that smoke and fumes are taken from the stove up the chimney and emitted safely into 
the atmosphere. Do not run at full output for at least 24 hours.
On completion of the installation and commissioning ensure that the operating instructions for the stove are left 
with the customer. Ensure to advise the customer on the correct use of the appliance with the fuels likely to be 
used on the stove and notify them to use only the recommended fuels for the stove.
Advise the user what to do should smoke or fumes be emitted from the stove. The customer should be warned to 
use a fireguard to BS 6539 in the presence of children, aged and/or infirm persons.

Operating your stove- Westfire uniQ 23

initial lighting of your stove.

The heat-resistant paint on your stove will cure and harden during the first few firings of your appliance. The 
curing process produces a  good deal of smoke and odour,  it is therefore important that the first time you light 
your stove the room should be well ventilated. During the process it is important to open and close the stove 
door periodically (every 30mins) during the first couple of firings to prevent the door rope seal from sticking and 
coming away from the door. Once the heat-resistant paint has hardened the smell will disappear. This stove is 
NOT designed to be used with the door open, the stove door must be kept closed except when lighting the stove, 
adding firewood or removing ash in order to prevent flue gases from escaping.

Lighting your appliance
When lighting your appliance quality firelighters should be used (never use mentholated spirit, petrol or other 
flammable liquids). Lighting your stove with firelighters will be more reliable and easier than using paper.

to light your stove
The Westfire Uniq 23 has 3 air supplies to the stove. Two are controlled by levers at the front of the stove below 
the door. The 3rd air supply is fixed, this tertiary air injects air in the rear of the stove through 4 holes.

Prepare your stove for lighting

1. Place a few smaller pieces of dry wood (kindling) in 
the stove on top of the non toxic firelighters, place one 
or two small dry split (¼ split) on top.

2. Fully slide open (pull out fully) the secondary air 
lever. 

3. Fully slide open fully the primary air. The stoves air 
supplies are now fully open.

4. Light the firelighters and push door to closed posi-
tion but do not close latch, this will allow a small gap 
of 1cm for more air to be supplied to stove.

uk

Содержание WF23

Страница 1: ...TFIRE WF23 1 dansk ingeniørkunst DK INSTALLATIONS OG BRUGSVEJLEDNING WF23 UK INSTALLATION MANUAL AND OPERATING INSTRUCTIONS D INSTALLATIONS UND GEBRAUCHSANWEISUNG fr NOTICE D INSTALLATION ET D UTILISATION ...

Страница 2: ... WF23 DK INSTALLATIONS OG BRUGSVEJLEDNINg 3 WF23 UK INSTALLATION MANUAL AND OPERATING INSTRUCTIONS 6 D INSTALLATIONS UND GEBRAUCHSANWEISUNG 17 fr NOTICE D INSTALLATION ET D UTILISATION 20 WESTFIRE 2011 wf23 1 0 ...

Страница 3: ...gningsreglementet Bygningsreglementet siger at ved lukkede ildsteder skal brændbare gulve dækkes mindst 30 cm foran fyringsåbningen og mindst 15 cm til hver side Under laget skal være af ikke brændbar materiale f eks stålplade glasplader klinker eller kunstskiferplade Norge Under platen av ubrennbart materiale skal brennbart gulvbelegg fjernes Montering af indsats Min højde fra brandbar gulve er m...

Страница 4: ...ørg derfor for en god udluftning De bør ligeledes holde lågen lidt åben under de første par påfyringer og først lukke når ovnen er kold så undgår De at paksnoren klæber sig fast til ovnen og går løs Når den varmebestandige maling er hærdet skal lågen holdes lukket undtagen under optænding brændselspåfyldning og fjernelse af restmaterialer for at forhindre udslip af røggas Inden optænding åbnes luf...

Страница 5: ...ides p g a overophedning dette kan ligesom andre lakskader repareres med en speciel senothermlak på spraydåse som kan købes i alle pejseforretninger Norge Aske skal kun oppbevares i ubrennbar beholder og skal ikke blandes med annet brennbart avfall Der er monteret skamolplader i brandkammeret Disse plader vil med tiden blive nedslidte og skal udskiftes Det samme gælder røgvenderpladen Hvis De komm...

Страница 6: ...ith current Building Regulations Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove It should be noted that the Building Regulations requirements may be met by adopting the relevant recommendations given in British Standards BS 8303 BS 6461 and BS 7566 as an alternative means to achieve an equivalent level of performance to that obtained fo...

Страница 7: ...tal 3 UNIQ 23 50mm legs on wood store Height 1050mm 850mm 1000mm Width 550mm 550mm 1000mm Depth 380mm 380mm 450mm Closed combustion available as option Yes Yes Yes STOVE PERFORMANCE TESTING Westfire UNIQ 23 have been approved in accordance with EN 13240 Stove model Weight Nominal heat output Wood Smokeless fuel UNIQ 23 100mm 50mm 300mm 92kg 6 1 KW N A UNIQ 23 Pedestal models 112kg 6 1KW N A WESTFI...

Страница 8: ...uired seeking expert advice If it is found necessary to line the chimney then a flue liner suitable for solid fuel must be used in accordance with Building Regulations Approved Document J Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of the stove by a professional chimney engineer If the stove is fitted in place of an open fire then the...

Страница 9: ...on air This is particularly necessary if the room is double glazed or a flue draught stabiliser is operating in the same room as the appliance The provision of air supply to the stove must be in accordance with current Building Regulations Approved Document J An opening window is not appropriate for this purpose Air inlets must be positioned in such a way that they cannot be blocked An air inlet m...

Страница 10: ...hould be warned to use a fireguard to BS 6539 in the presence of children aged and or infirm persons Operating your stove WESTFIRE UNIQ 23 Initial lighting of your stove The heat resistant paint on your stove will cure and harden during the first few firings of your appliance The curing process produces a good deal of smoke and odour it is therefore important that the first time you light your sto...

Страница 11: ...condary air intake correctly as factors such as the quality and height of your chimney the quality of your fuel and the external conditions play a large role in your stove performance It is easy to see whether the stove is functioning correctly as the stove will burn cleanly and the internal fire chamber will remain clean however incomplete combustion may lead to a build up of hard shiny soot on t...

Страница 12: ...areas have been authorised in Regulations and that appliances used to burn solid fuel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations The Westfire Uniq 23 23 side glass 23 inset are recommended as suitable for use in smoke control areas when burning wood logs Further information on the r...

Страница 13: ... The stove will burn best when burning wood HOUSE COAL AND PETROLEUM COKE ARE NOT SUITABLE FOR USE ON THIS STOVE ITS USE WILL INVALIDATE THE GUARANTEE Heat Protective glove Always use the heat protective glove provided when handling parts likely to be hot when the stove is in use Maintenance WESTFIRE UNIQ 23 stove needs to have the ash removed from the stove at regular intervals Make sure the stov...

Страница 14: ...e minimum setting e the air inlet lever is closed and that it is not prevented from closing completely by a piece of ash f a suitable fuel is being used no finished wood pallet wood g the chimney draft may be too strong fit draught stabiliser 12 pa 3 Soot forms on the window a The firewood may be too wet b the intake of secondary air may be insufficient c fire is not hot enough 4 The stove fails t...

Страница 15: ...keless fuels and a minimum of twice a year for wood and other fuels It is important that the flue connection and chimney are swept prior to lighting up after a pro longed shutdown period If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove a...

Страница 16: ...ce with a steel pin Left right mid baffle bricks 2 3 positioned with full angled edge at front and part angled edge on the outside Bricks 2 3 need to be fitted lower down and slid upwards into final position Rear brick 4 positioned lining up tertiary air holes with angled edge sloping down at rear Left base brick 5 positioned Left side brick 6 positioned on top of left base brick 5 Left mid baffle...

Страница 17: ...nbaren Fußböden und der Ofenunterkante muss der Abstand mindestens 500 mm betragen Der Einsatz darf nur in eine Wand aus nicht brennbaren Materialien eingebaut werden Die Öffnung für den Einsatz muss mindestens 60 x 61 x 37 5 cm H B T groß sein Der Fußboden muss dort wo der Kaminofen stehen soll ausreichend tragfähig sein Der Abstand zu brennbaren Materialien gem EN 13240 geht aus dem Schild auf d...

Страница 18: ...us Benzin oder andere feuergefährlichen Flüssigkeiten unter keinen Umständen verwendet werden dürfen Legen Sie einige kleinere Holzstücke über Kreuz auf die Kaminanzünder Wenn alles gut brennt werden 2 weitere Holzstücke von ca 33 cm Länge Gewicht ca 1 5 kg aufgelegt Nach ca 4 Minuten wird der Lufteinlass für die Anzündephase geschlossen und die Regulierstange in der Mitte zu etwa 40 eingeschoben ...

Страница 19: ...derem bren nbaren Abfall in Berührung kommen Der Feuerraum ist mit Platten der Fa Skamol ausgekleidet Da sich diese Platten mit der Zeit abnutzen müssen sie ausgetauscht werden was im Übrigen auch für die Rauchumlenkplatte gilt Wenn man ein Holzstück zu heftig in den Ofen wirft kann es passieren dass eine Skamol Platte einen Riss bekommt Das wirkt sich jedoch nicht auf die Verbrennung aus sofern d...

Страница 20: ...strable ne peut être monté que sur un mur construit en matériau non inflammable La taille minimum du trou pour le montage du poêle encastrable est de 60 cm en hauteur 61 cm en largeur et 37 5 cm en profondeur Les sols sur lesquels sont installés les poêles doivent être d une portée suffisante pour supporter le poids du poêle La distance entre le poêle et le matériau inflammable est indiquée sur l ...

Страница 21: ... allumer votre poêle Placez de petits morceaux de bois en travers du poêle au dessus des briquettes d allumage Une fois que le feu a bien pris placez deux morceaux de bois de 33 cm environ pesant en tout environ 1 5 kg Après 4 minutes environ fermez le dispositif d allumage et repoussez le levier de régulation situé au milieu d environ 40 Le rechargement de combustible se fait une fois par heure à...

Страница 22: ... peut arriver que l une des plaques Skamol se fende après avoir été heurtée trop violemment par un morceau de bois Cela n a pas d incidence sur la combustion ce qui n est pas le cas de l inverseur de fumées Lorsque les plaques Skamol sont si usées qu elles ne sont plus entières il est temps de les remplacer C est également le cas lorsque les plaques sont fendues à plusieurs endroits En cas de surc...

Страница 23: ...WESTFIRE WF23 23 ...

Страница 24: ...24 Tømrervej 3 DK 6800 Varde telefon 45 7522 5352 fax 45 7522 1352 www westfire dk e mail info westfire dk WESTFIRE 2011 wf23 1 0 Der tages forbehold for trykfejl 16947 Mediegruppen Reklamebureau ...

Отзывы: