![Westfire WF23 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/westfire/wf23/wf23_installation-manual-and-operating-instructions_963956014.webp)
WESTFIRE · WF
23
WESTFIRE · WF
23
14
trouble shooting
1. fire Will not Burn - check
a)
the air inlet is not obstructed in any way,
b)
that chimneys and flueways are clear,
c)
that a suitable fuel is being used,
d)
that there is an adequate air supply into the room,
e)
that an extractor fan is not fitted in the same room as the fire.
2. fire Blazing Out Of Control - check
a)
the door is tightly closed and door seal is in good condition
b)
the ashpan for ash under pan, clean out ashpan chamber with vacuum.
c)
the ash pan drawer seal is tight.
d)
the air control is turned down to the minimum setting,
e)
the air inlet lever is closed and that it is not prevented from closing completely by a piece of ash,
f)
a suitable fuel is being used, ( no finished wood, pallet wood)
g)
the chimney draft may be too strong – (fit draught stabiliser 12 pa)
3) soot forms on the window
a)
The firewood may be too wet
b)
the intake of secondary air may be insufficient
c)
fire is not hot enough
4) the stove fails to heat fully
a)
The firewood may be too wet
b)
the intake of secondary air may be insufficient
5) smoke or odour
a)
Weak chimney draft
b)
check for blockages in the flue pipe/chimney
c)
check the height of the chimney in relation to the surroundings
6) soot in the chimney
a)
The firewood may be too wet
b)
intake of secondary air may be insufficient
uk