background image

Safety Notes 

 

 

 

Make sure the voltage corresponds to the type label on the device. 

 

Persons  with limited physical, sensorial or mental  abilities are  not  allowed to 
use  the  device,  unless  they  are  supervised  and  briefed  for  their  safety  by  a 
qualified person. 

 

The  sliding  gate  opener  is  designed  for  opening  and  closing  light-weighted 
sliding gates only. The sliding gate opener is designed for private use only. 

 

The  sliding  gate  opener  is  designed  for  operating  sliding  gates  in  vehicle 
drives. Pedestrians must use a separate entrance. 

 

Mounting,  maintenance  and  repairs  of  the  sliding  gate  opener  must  be 
performed by a qualified person. According to EN 12635, a qualified person is 
a person with suitable training, specialist knowledge and practical experience 
sufficient to correctly and safely fit, test and maintain the gate system. In case 
of failure of the sliding gate opener, a qualified person must be commissioned 
immediately  for  the  inspection  or  repair  work.  Observe  the  local  safety 
regulations  to  prevent  accidents  while  mounting  the  sliding  gate  opener. 
Westfalia  assumes  no  liability  for  improper  installation  of  the  sliding  gate 
opener. 

 

WARNING. There is risk on injuries if the sliding gate opener is not mounted 
and  operated  correctly.  Incorrect  mounting  and  operation  of  the  sliding  gate 
opener  may  trigger  unexpected  gate  travel.  Thus  persons  or  objects  can  be 
trapped. 

 

Do not modify the sliding gate opener in any way.  

 

Electrical  installation  has  to  be  carried  out  by  a  qualified  professional  only. 
Power  supply  of  the  sliding  gate opener  is  provided  by  means  of  230  V~  50 
Hz or by means of two batteries. Electrical power should be reserved only for 
the sliding gate opener and should be protected by a 10 A fuse. 

 

Check  the  whole  sliding  gate  system  (joints  mounting  material  etc.)  for  any 
signs  of  wear  or  damages  and  do  not  use  the  sliding  gate  opener  with  a 
damaged  sliding  gate system resp. with signs  of  rust,  fractures  or  corrosion. 
Do not use the sliding gate opener unless repair work or alignment is carried 
out properly. 

 

Disable the existing sliding gate locks in order to avoid damages on the gate. 

 

Ensure  proper  mounting  when  installing  the  sliding  gate  opener.  Check  the 
sliding  gate  for  proper  manual  operation.  It  is  essential  that  the  sliding  gate 
can be easily opened and closed by hand. 

 

Please  note  the  following  safety  notes  to  avoid  malfunctions, 
damage or physical injury 

Содержание 82 63 73

Страница 1: ...Sliding Gate Opener Article No 82 63 73 Instruction Manual Nylon Racks not included in Delivery...

Страница 2: ...ructions for further reference This operating instruction contains important details for handling the device Please pass it on along with the unit if it is handed over to a third party Please read all...

Страница 3: ...r Gate may move at any time 2 Do not allow children to operate the gate or play in the gate area 3 The gate area is for vehicles only 4 Read and understand the manual 5 Pedestrians have to use a separ...

Страница 4: ...ece 6 Warning Sign 1 Piece in German 1 Piece in English 7 Magnet Bracket 2 Pieces 8 M8 x 70 Screw 4 Pieces 9 Washer 8 mm 8 Pieces 10 Spring Washer 8 mm 8 Pieces 11 M8 Nut 4 Pieces 12 Magnet Limit Swit...

Страница 5: ...8 Power Connection Page 11 Position of the DIP Switches Page 13 Programming Page 14 Position of the Magnets Page 16 Potentiometer Page 18 Hindrance Detection Page 19 Learning the Remote Control Page 2...

Страница 6: ...proper installation of the sliding gate opener WARNING There is risk on injuries if the sliding gate opener is not mounted and operated correctly Incorrect mounting and operation of the sliding gate o...

Страница 7: ...not completely opened or closed Do not allow children to stand or play in the gate s moving range Make sure movement of the gate and proper function of the sliding gate opener are not impaired by obs...

Страница 8: ...own safety the sliding gate system has to be checked by a qualified person every 6 months for proper function The gate must reverse on contact with a right object If necessary existing errors resp da...

Страница 9: ...be in good mechanical and trouble free condition and should not be damaged or has signs of wear It must be possible to open and close the gate by hand without any problems The mechanical gate lock mu...

Страница 10: ...the gate system 5 Built a concrete pad of approx 50 x 32 x 35 cm see drawing on page 7 The concrete pad should be at least 10 cm over the ground Increase the pad height if necessary to protect the ga...

Страница 11: ...Mounting Diagram 7 Sliding Gate Opener x x x Mounting Screws x Mounting Plate Cable Cable Channel Concrete Pad...

Страница 12: ...er function of the sliding gate opener and the correct position of the magnet limit switch can be checked 1 For releasing the sliding gate opener first remove the cap 2 Insert the included releasing k...

Страница 13: ...orizontal on the gearwheel Never use fat or other lubricating agents between the gearwheel and the rack 5 Adjust the other racks too Make sure the teeth of the racks engage the gearwheel throughout th...

Страница 14: ...Magnet Bracket 7 Self securing Screws included in delivery or use screws and nuts that are suitable for the existing gate Magnet 12 Gate Opener 1 Magnet Limit Switch Mounting Plate Concrete Pad Rack...

Страница 15: ...11 Connecting to Power Supply The connection cables must not be smaller than H05 3 x 0 75 mm 2 Connect the cable for live wire with L Connect the cable for neutral wire with N Connect the cable for e...

Страница 16: ...m the motor has to be connected with terminal 1 Green cable from the motor has to be connected with terminal 2 When using Batteries Terminal of the batteries has to be connected with terminal 8 Termin...

Страница 17: ...the sliding gate opener Disconnect power supply from the gate opener before changing the setting Always keep away from the moving path of the sliding gate opener in order to avoid injuries in case of...

Страница 18: ...iding Gate Opener in Midway Mode 6 Seconds 2 4 Seconds DIP Switch 3 ON 0 5 Seconds OFF 0 Second DIP Switch 4 ON 1 Second OFF 0 Second DIP Switch 5 ON 2 Seconds OFF 0 Second Factory Default of the swit...

Страница 19: ...fault of both switches is OFF Automatic Closing Time is disabled Open Opens to the right Open Opens to the left DIP Switch 6 7 Automatic Closing Time DIP Switch 8 Factory default of the DIP switch 8 i...

Страница 20: ...osition them correctly the sliding gate opener must be mounted properly Disengage the gearwheel and disconnect power supply Mount both magnets on the desired positions on the gate See the drawing belo...

Страница 21: ...not be more than 2 cm away from the magnetic limit switch otherwise proper function cannot be guaranteed The distance between the magnets and the sliding gate opener has to be between 10 15 mm If nec...

Страница 22: ...the respective potentiometer clockwise for increasing the stall force and counter clockwise for decreasing the stall force The increase in the stall force is a percentage increase in relation to the...

Страница 23: ...will be For checking the hindrance detection proceed as follows 1 Place a rigid object along the gate path and operate the sliding gate opener until it touches the rigid object while opening resp clos...

Страница 24: ...ton A on the remote control for the following functions Gate open Stop Gate close Stop Gate open 2 If the DIP switch settings 1 and 2 for normal run are activated press the button B for the following...

Страница 25: ...ure proper function of the gate opener Keep in mind that operating the sliding gate opener beyond the permissible operating temperature range of 15 C 40 C functional problems can result e g icing of t...

Страница 26: ...Special Accessory 22 The special Accessory is not available at Westfalia...

Страница 27: ...Diagram for Connecting Special Accessory 23...

Страница 28: ...r Gate Moving Speed 17 cm per Second Self locking Gearbox Yes Max Gate Weight 400 kg Operating Temperature 15 C 40 C Protection Class IP44 Dimensions of the Gate Opener 20 x 20 x 20 cm Weight 5 3 kg T...

Страница 29: ...ener Article No 82 63 73 is according to the basic requirements which are defined in the European Directives 2006 95 EC Low Voltage Directive LVD 1999 5 EC R TTE Directive 2011 65 EU Restriction of th...

Страница 30: ...nternet www westfalia net Kundenbetreuung Customer Services is Werter Kunde bitte helfen Sie mit Abfall zu vermeiden Sollten Sie sich einmal von diesem Artikel trennen wollen so bedenken Sie bitte das...

Отзывы: