Lit. No. 28270, Rev. 00
July 1, 2005
28
WARNING
To prevent accidental
movement of the blade, always
turn the ON/OFF switch to OFF
whenever the snowplow is not
in use. The control indicator
light will turn off.
JOYSTICK CONTROL
1. Turn the vehicle ignition switch to
the ON or the ACCESSORY
position.
2. Move the slide switch on the side
of the control to the ON position.
The control ON/OFF indicator
light glows red, indicating the
control is on. The indicator light
glows red whenever the control
and the vehicle ignition switch
are both on and the electrical
connections to the plow are
completed.
The ON/OFF switch operates as
an emergency stop if required.
Function Time Outs
All control functions, except
LOWER/Float, time out (stop)
automatically after a period of time.
This is to limit the amount of
electrical energy required from the
vehicle. The time-out period for the
RAISE function is 3.0 seconds, while
all others are 5.5 seconds.
NOTE: If control function times out
before desired blade movement is
complete, refer to the General
Diagnostic Table in the
Troubleshooting section of this
guide.
Automatic Shutdown
The control will automatically turn off
after being idle for 20 minutes. To
reactivate the control after a shut
down, move ON/OFF switch to OFF,
then back to ON.
Smooth Stop
The control automatically allows the
blade to coast to a stop when the
lever returns to center position. This
results in smoother operation,
reduces the shock to the hydraulic
system and increases hose and
valve life.
Power
Indicator
Light (red)
ON/OFF
Switch
(Emergency
Stop)
Control Lever Movement
From the center position, the control
lever can be moved in one of eight (8)
directions to control various
movements of the snowplow blade. To
change from one movement of the
blade to another, the control lever
must be moved back to the center
position before selecting the desired
function. Whenever the lever is
released, it should spring back to the
center position to stop blade
movement.
SYSTEM OVERVIEW – CONTROLS