Lit. No. 48163, Rev. 00
March 15, 2016
100
HYDRAULIC SYSTEM TEST
This test consists of trying all the plow functions
and comparing the plow reaction to the action
requested. The following table will help you
pinpoint a solenoid valve or poppet check valve
problem accurately if
only one
component is
malfunctioning.
If the plow reaction for a given function is not listed
in the table, the problem may be caused by a
crossover relief or poppet check valve that is stuck
open or contaminated, or by missing or damaged
O-rings or backing rings on a cartridge, crossover
relief or poppet check valve spool.
Another possibility is that there are
two or more
malfunctioning components. In this case, use
the specific function hydraulic schematic and
carefully inspect each component in the flow
circuit. If contamination is evident in more than one
component, the hydraulic unit, hoses and cylinders
must be completely disassembled, inspected and
cleaned.
1. Perform the
Cartridge Coil Activation Test
first.
2. Verify that hydraulic hose installation is correct.
Action Requested Plow Reaction
Possible Cause
Raise
None
S3 not shifted
Angle left
S2 stuck shifted
Lower
None
S1 not shifted
S2 stuck shifted
S3 stuck shifted
Angle right
Angle left
S3 stuck shifted
None
S2 not shifted
Slow
Poppet check valve not opening
Angle left
Angle right
S3 not shifted
Raise
S2 not shifted
None
S2 and S3 not shifted
Slow
Poppet check valve not opening
None (blade raised)
Lowers
S1 stuck shifted or has leaking internal check valve
None
Drifts right
S2 stuck shifted
Contamination, bad valve stem seat, or damaged O-rings in crossover relief valve
Drifts left
Poppet check valve open
Contamination, bad valve stem seat, or damaged O-rings in crossover relief valve
3.
Test all of the plow functions. IMPORTANT:
When testing the plow functions, be sure the
control is
not
in FLOAT.
4.
Inspect and clean or replace the suspected
component. Refer to the FloStat
®
Hydraulic
Unit Hydraulic Components diagram in the
Hydraulic System Overview section.
5.
Refer to the following pages for instructions on
testing, inspection and adjustment of solenoid
cartridge valves, poppet check valves and
crossover relief valves.
Содержание Midweight Series
Страница 2: ......
Страница 34: ...Lit No 48163 Rev 00 March 15 2016 34 This page intentionally left blank...
Страница 35: ...Lit No 48163 Rev 00 March 15 2016 35 Electrical Hydraulic Schematics...
Страница 36: ...Lit No 48163 Rev 00 March 15 2016 36 This page intentionally left blank...
Страница 43: ...Lit No 48163 Rev 00 March 15 2016 43 3 PLUG SYSTEM HYDRAULIC SCHEMATIC...
Страница 45: ...Lit No 48163 Rev 00 March 15 2016 45 RAISE HYDRAULIC 3 PLUG SYSTEM...
Страница 47: ...Lit No 48163 Rev 00 March 15 2016 47 LOWER FLOAT HYDRAULIC 3 PLUG SYSTEM...
Страница 49: ...Lit No 48163 Rev 00 March 15 2016 49 ANGLE RIGHT HYDRAULIC 3 PLUG SYSTEM...
Страница 51: ...Lit No 48163 Rev 00 March 15 2016 51 ANGLE LEFT HYDRAULIC 3 PLUG SYSTEM...
Страница 60: ...Lit No 48163 Rev 00 March 15 2016 60 2 PLUG SYSTEM HYDRAULIC SCHEMATIC...
Страница 62: ...Lit No 48163 Rev 00 March 15 2016 62 RAISE HYDRAULIC 2 PLUG SYSTEM...
Страница 64: ...Lit No 48163 Rev 00 March 15 2016 64 LOWER FLOAT HYDRAULIC 2 PLUG SYSTEM...
Страница 66: ...Lit No 48163 Rev 00 March 15 2016 66 ANGLE RIGHT HYDRAULIC 2 PLUG SYSTEM...
Страница 68: ...Lit No 48163 Rev 00 March 15 2016 68 ANGLE LEFT HYDRAULIC 2 PLUG SYSTEM...
Страница 72: ...Lit No 48163 Rev 00 March 15 2016 72 Hydraulic Pump Repairs...
Страница 78: ...Lit No 48163 Rev 00 March 15 2016 78 Troubleshooting...
Страница 103: ......