SECTION 3
DISASSEMBLY AND FOLDING OF THE TENT
3.1
DEFLATING THE TENT
The tent is obviously disassembled by reversing the assembly operation.
A -
Firstly disassemble the internal accessories (dust mat, electric system). The insulation liners and the air distribution
system can remain fitted inside the tent. Then clean the bottom of the tent.
B -
Remove the sunshade as shown in paragraph 2.3 and put it back in its bag after folding it properly.
C -
Remove the entrance module and put it back in the proper bag.
D -
Close the doors, the curtains and the transparent window panels, and fasten them with the specific closing systems with
which they are provided (braids, eyelets, loops and Velcro).
E -
Remove all the stakes (from the base of the tent and from the guy lines), clean them and put them back in their bag.
F -
Partially deflate the arches from the external valves leaving the tent partially and stability standing.
G -
Remove the side spacer rods from the tent and put them in the pole bag.
H -
Fully deflate the supporting arches and lock the external valve shutters in the open position. Position the tent as it
deflates inside the footprint.
I -
Fully deflate the sunshade pneumatic spacers.
J -
Extract the inflation tube manifold and install it on the suction manifold (with the word “inlet”) (fig. 3.1).
K -
After closing the inflation valve shutters, press the tubes into the valves of the spacers and then into those of the arches
(fig. 3.2). Turn the taps to open position.
L -
Run the inflator until the spacers and/or arches are fully deflated.
M -
Switch the inflator off and rapidly disconnect the tubes from the inflation valves.
N -
Extract the tube from the inflator.
CAUTION! WHEN DEFLATING WITH THE ELECTRIC INFLATOR, BE VERY CAREFUL NOT TO SUCK DUST, DEBRIS,
LIQUIDS OR OTHER MATERIALS INTO THE TUBE.
NOTE:
THIS OPERATION MAY ALSO BE PERFORMED WITH THE MANUAL PUMP BY REVERSING THE DIRECTION OF
INFLATION AND POSITIONING THE CORRUGATED TUBE INTO THE SUCTION HOLE OF THE INFLATOR.
Figure 3.1 - Inflator tube engagement for deflation
Figure 3.2 - Inflation valve tube pressure
engagement
Содержание AIRFRAME SENTINEL II
Страница 1: ...Inflatable Shelter TECHNICAL MANUAL HEAVY DUTY INFLATABLE SHELTER SYSTEM P N SW SII 2015...
Страница 2: ...D P...
Страница 8: ...ILLUSTRATED PROCEDURE FOR SHELTER DEPLOYMENT...
Страница 9: ......
Страница 10: ......
Страница 12: ...ILLUSTRATED PROCEDUREFOR SHELTER INFLATION...
Страница 15: ...1 2 3 4 Figure 2 10 Assembly sequence of inner insulating liner for TAG NG 4 arches tent...
Страница 17: ...Figure 2 12 Installed sunshade diagram Figure 2 13 Noose and knot on guy rod diagram at...