background image

3.Lock

If

 

no

 

operation

 

with

 

the

 

control

 

panel

 

for

 

3

 

minutes

all

 

the

 

keys

 

will

 

be

 

locked

 

except

 “

LOCK

”,

LCD

 

displays

 “

LOCK

”.

When

 

the

 

keys

 

were

 

locked

press

 

any

 

key

 

for

 

3

 

seconds

the

 

keys

 

will

 

be

 

unlocked

 

after

 

a

di

…”

icon

LOCK

disappear

.

4

.

Ozone

 

(

FM radio on

ozone will be turned off automatically)

4.1 When

 

the

 

system

 

is

 

on

press

 

continuously

 

“    、  ”,

when

 

the

 

cursor

 

is

 

on

“   ”

press“        ”ozone

 

will

 

be

 

started

And

 

LCD

 

symbol

 

will

 

be

 

displayed

 

dynamically

.

Press 

“    ”

again

ozone will be turned off.

4.2 ozone will be turned off automatically after being started 10 minutes.

5 .Blower

When the system is on, press continuously “

    

” “        ”till the cursor moved

 to “      ”,and then press “

  

 

 

”to start the blower

the cursor blinks

press again, 

blower is stopped.

6 .Water pump surf

6.1 The water checking device of this controller protects the water pump from 
burning out.
6.2 When the system is on, press“        ” “         ”till the cursor moved to “ 

     

”,while 

the water level achieves the setting value ,and then press “              ”to start the 
pump

the cursor blinks

press again, Water pump surf is stopped.

6.3 When the water level lowers than the setting value, pump stops working.
6.4 When the water surf pump function is on, and the system checks the water 
level lower than the setting value, water surf pump function stops automatically, 
at the same time the pump icon blinks.When any time the system checks the water 
level achieves the setting value, the icon stops blink and the pump starts to work.

7 .FM Radio

7.1 The FM frequency scope is 87.5MHz—108.0MHz.
7.2 When the system is on, press “ 

      

” “       ”till the cursor moved to “        ”, and

then press “ 

       

” to turn on the FM Radio Function, at the same time, the LCD 

displays the current frequency and “FM”; press the icon “        ”again ,FM function 
stops while the current frequency and “FM” disappears.
7.3 When the FM function is on, press “        ” till the LCD blinks “FM” and “MHZ”, 
the system enter into the state of adjusting the frequency.
7.3.1 press “        ” to increase the length of one step (the length of one step
 =100KHz): Press this button over 2 seconds, the system searches the radio 
stations of larger frequencies automatically; the digital phase locked loop will lock
the FM station automatically and the LCD shows the present frequency, when it 
reaches to the limit of 108.0MHz, press this button again
and the frequency jumps to 87.5MHz.
7.3.2 Press “       ” to decrease the length of one step (the length of one step 
=100KHz).Press this button over 2 seconds, the system searches the radio stations
of smaller frequencies automatically; the digital phase locked loop will lock the FM 
station automatically and the liquid crystal shows the frequency of this station; 
When it reaches to the limit of 87.5MHz, press this button again and the frequency
 jumps to 108.0MHz.

Manual

6

Содержание SYM0502A

Страница 1: ...MODEL SYM0502A INSTALLATIONINSTRUCTION MASSAGE BATHTUB MASSAGE BATHTUB...

Страница 2: ...ir conditioning 6 pillow water pump 7 drainage 8 shower 13 CAUTIONS Heat pump and air bubble pump is required by customers 9 tap 10 drainage switch 11 hot water switch 12 shift switch 13 cold water sw...

Страница 3: ...wood panel 2 Manual 150 450 450 1500 650 500 500 drainage CAUTIONS Heat pump and air bubble pump is required by customers cold water hot water tap shower SIZE 1800 1500 700mm 1800 900...

Страница 4: ...urately 3 Please put this controller in a ventilated dry area Prevent it from getting close to the heat source put it away from direct sunlight mechanical vibration dampness and dusty environment and...

Страница 5: ...ler otherwise it will not work or even burn out the controller 5 If it is halted accidentally please close and restart II Brief Introduction 1 Controller System Including 1 Control panel 1 2 Control b...

Страница 6: ...troller is found can not be used please operate the code checking with following instruction Code checking procedure Power must be off to the bathtub before the below procedure Press the power icon on...

Страница 7: ...ically at the same time the pump icon blinks When any time the system checks the water level achieves the setting value the icon stops blink and the pump starts to work 7 FM Radio 7 1 The FM frequency...

Страница 8: ...ted by press and to choose from 1 18 all 18stations 7 5 5 When pressing and entering a certain function state within 5 S without pressing system will automatically exit that function operation state O...

Страница 9: ...P N by pressing to choose nest song by pressing to choose the last song by press and next song and last song can also be chosen 9 5 When the blue tooth music is started pressing for 2S to play or paus...

Страница 10: ...ed by illegal manufacturers must not be connected to the controller Unapproved dismantling and modification of the enclosed internal wiring are strictly prohibited It is not allowed to connect or plug...

Страница 11: ...n be removed 3 install a new water pump Water Jets are not working 1 check the system whether is on 2 the impeller of water pump doesn t rotate 3 water pump is broken which caused by working without w...

Страница 12: ...ularly in order to avoid troubles from crack of water pipes or blocked inside 6 If there are something such as hair stuck inside the jets then just to twist out the jets and remove it 7 To clean hydro...

Отзывы: