7.4 When the FM radio is on, press“       ”till the LCD blinks “VOL”, and then press “ 

   

to increase the volume and press “       ”to decrease the volume. The volume adjusting
 range is 0-20, and 21 in total.
7.5 Station storage/select
7.5.1 Station storage

when FM function is on and select the station frequency to be 

stored,press “ 

   

” to select the location for storage “CH”and number below it shall 

blink, and press the icon “ 

   

” “      ”to choose the location(1-18,all18 ); press the icon

“        ”, the station frequency shall be stored in the selected storage location.And LCD
 will  resume to current frequency.
7.5.2 station storage

when the station to be stored is chosen, press“        ”for 2S 

on the remote controller. LCD blinks with“CH”and the number below

the system 

entering station  storage state. By pressing 

“      ” 

on the controller to adjust the 

storage   position(1-18,totally 18). When the position is chosen, pressing 

“        ” 

for 

2Sthen the storage is done and LCD resume to display station frequency.
7.5.3 Station select

in FM state

press“         ”. When LCD displays“CH”

select

the according stored station (1-18,totally 18).
7.5.4 Station select

When FM function is on

press “ 

    

” the corresponding 

stored station  can be selected by press“       ”and 

     

 ”

to choose from

 (1-18,all 18stations)
7.5.5 When pressing 

“       ”

and entering a certain function state, within 5 S without

pressing 

“     ”

“     ”

 

system will automatically exit that function operation

state.Or by pressing“        ”function choosing key to exit that function.

.

Thermostatic heating

8.1 This functions works only when the water pump surf function is on.
8.2 Press “ 

      

” “      ” till the cursor moved to “        ”,and then press “   

   

 ”to start the

thermostatic heating function.
8.2.1 Thermostatic heating function starts or stops according to the water 
temperature and set temperature

the temperature that the system defaults is 37

Controlling rule is as follows:
If the temperature

setting temp1

℃,

stop heating and LCD heating symbol 

blinks

If the temperature

setting temperature -1

℃,

start heating and LCD heating symbol 

displayed in dynamical way.
8.3 Press “       ” again to stop the function.
8.4 Temperature adjustment
8.4.1 When the thermostatic heating function is on, press “       ”till “

”on LCD blinks,

then press “ 

     

”or“       ” to adjust the temperature. During the adjusting, LCD 

ddisplays the setting temperature, then the temperature shall be increased /
decreased 1 

℃ 

after   press“

     

 ” “       ”once

When pressing“       ”or“      ”more that 

2S

the temperature will increase or decrease by“1

℃ 

/0.5s”

stop adjusting for 

5 seconds

LCD shall display the current water temperature and system exit 

temperature adjustment.

Manual

7

Содержание SYM0502A

Страница 1: ...MODEL SYM0502A INSTALLATIONINSTRUCTION MASSAGE BATHTUB MASSAGE BATHTUB...

Страница 2: ...ir conditioning 6 pillow water pump 7 drainage 8 shower 13 CAUTIONS Heat pump and air bubble pump is required by customers 9 tap 10 drainage switch 11 hot water switch 12 shift switch 13 cold water sw...

Страница 3: ...wood panel 2 Manual 150 450 450 1500 650 500 500 drainage CAUTIONS Heat pump and air bubble pump is required by customers cold water hot water tap shower SIZE 1800 1500 700mm 1800 900...

Страница 4: ...urately 3 Please put this controller in a ventilated dry area Prevent it from getting close to the heat source put it away from direct sunlight mechanical vibration dampness and dusty environment and...

Страница 5: ...ler otherwise it will not work or even burn out the controller 5 If it is halted accidentally please close and restart II Brief Introduction 1 Controller System Including 1 Control panel 1 2 Control b...

Страница 6: ...troller is found can not be used please operate the code checking with following instruction Code checking procedure Power must be off to the bathtub before the below procedure Press the power icon on...

Страница 7: ...ically at the same time the pump icon blinks When any time the system checks the water level achieves the setting value the icon stops blink and the pump starts to work 7 FM Radio 7 1 The FM frequency...

Страница 8: ...ted by press and to choose from 1 18 all 18stations 7 5 5 When pressing and entering a certain function state within 5 S without pressing system will automatically exit that function operation state O...

Страница 9: ...P N by pressing to choose nest song by pressing to choose the last song by press and next song and last song can also be chosen 9 5 When the blue tooth music is started pressing for 2S to play or paus...

Страница 10: ...ed by illegal manufacturers must not be connected to the controller Unapproved dismantling and modification of the enclosed internal wiring are strictly prohibited It is not allowed to connect or plug...

Страница 11: ...n be removed 3 install a new water pump Water Jets are not working 1 check the system whether is on 2 the impeller of water pump doesn t rotate 3 water pump is broken which caused by working without w...

Страница 12: ...ularly in order to avoid troubles from crack of water pipes or blocked inside 6 If there are something such as hair stuck inside the jets then just to twist out the jets and remove it 7 To clean hydro...

Отзывы: