background image

www.westermo.com

Lynx DSS L208-F2G-S2-EX 

Industrial Ethernet 8-port Device Server Switch

Содержание Lynx DSS L208-F2G-S2-EX

Страница 1: ...www westermo com Lynx DSS L208 F2G S2 EX Industrial Ethernet 8 port Device Server Switch...

Страница 2: ...2 6643 22701...

Страница 3: ...can be found at www westermo com Software tools Related software tools are available at www westermo com support software tools License and copyright for included Free Libre Open Source Software This...

Страница 4: ...a potentially hazardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the produc...

Страница 5: ...ss sectional area of at least 4 mm2 If the product does not have a protective earthing terminal then the DINrail must be connected to protective earth Upon removal of the product ensure that the prote...

Страница 6: ...damages to internal electronic parts by discharging your body to a grounding point e g use a wrist strap CAUTION CLASS 1 LASER PRODUCT Do not look directly into a fibre optical port or any connected...

Страница 7: ...mendations Follow the care recommendations below to maintain full operation of product and to fulfill the warranty obligations Do not drop knock or shake the product Rough handling above the specifica...

Страница 8: ...vant requirements of EN 60079 0 and EN 60079 15 All external connections to the equipment and where applicable the SFP modules must not be inserted or removed unless either the area in which the equip...

Страница 9: ...ultimode BiDi 2 km 1310 nm TX 1550 nm RX 1100 0153 MLC2 BiDi B Multimode BiDi 2 km 1550 nm TX 1310 nm RX SFP Transceivers 1 Gbit 1100 0144 GMLC550 SX Multimode LC Connector 550 m 850 nm SX 1100 0147 G...

Страница 10: ...0079 15 erf llt installiert werden Alle u eren Anschl sse des Ger tes und auch die SFP Module d rfen nur dann verbunden oder getrennt werden wenn entweder der Bereich in dem das Ger t installiert ist...

Страница 11: ...A Multimode BiDi 2 km 1310 nm TX 1550 nm RX 1100 0153 MLC2 BiDi B Multimode BiDi 2 km 1550 nm TX 1310 nm RX SFP Transceiver 1 Gbit 1100 0144 GMLC550 SX Multimode LC Anschluss 550 m 850 nm SX 1100 0147...

Страница 12: ...et EN 60079 15 Toutes les connexions externes l quipement et le cas ch ant les modules SFP ne doivent pas tre ins r s ou retir s sauf si la zone dans laquelle l quipement est install est reconnue com...

Страница 13: ...Di A multimode Bi Di 2 km 1310 nm TX 1550 nm RX 1100 0153 MLC2 BiDi B multimode Bi Di 2 km 1550 nm TX 1310 nm RX Transmetteurs SFP 1 Gbit 1100 0144 GMLC550 SX multimode connecteur LC 550 m 850 nm SX 1...

Страница 14: ...source Enclosure TS1 Mechanical energy source Enclosure MS1 Radiation energy source SFP RS1 FCC Part 15 105 Notice This equipment has been tested and found to comply with the limits for a Class B digi...

Страница 15: ...n safety critical applications such as tunnels traffic signal control and railway systems Installations in harsh environments and places with heavy electrical interference require the use of a reliabl...

Страница 16: ...mitted Received data Per port U 1 V 4V s I 20 mA Data rate 10 100 Mbit s No 2 TD In Out Transmitted Received data No 3 RD In Out Transmitted Received data No 4 Not Connected No 5 Not Connected No 6 RD...

Страница 17: ...eive U 5 V max I 250 mA max Data rate 50 bit s 2 Mbit s No 2 T T R Out In RS 422 Transmit RS 485 Transmit Receive No 3 R In RS 422 Receive No 4 Not used No 5 Not used No 6 R In RS 422 Receive No 7 Not...

Страница 18: ...fication IEEE std 802 3 Data rate 10 Mbit s 100 Mbit s manual or auto Duplex Full or half manual or auto Circuit type TNV 1 Transmission range Up to 150 m with CAT5e cable or better Isolation to All o...

Страница 19: ...orts 1 To minimise the risk of interference a shielded cable is recommended when the cable is located inside 3 m boundary or the cable is longer than 30 m and inside 10 m boundary to the rails and con...

Страница 20: ...400 mA Connection USB receptacle connector type A Console Electrical specification LVTTL level service port shall not be connected during nor mal operation Only to be used during maintenance Data rate...

Страница 21: ...cohol hexane or naphtha Supported transceivers Firmware prior to 4 4 0 accepts Westermo branded transceivers only From 4 5 0 other transceivers are accepted with a notice and the product will no longe...

Страница 22: ...8 Enclosure 300 A m 0 16 7 60 Hz 1000 A m 50 Hz Pulsed magnetic field EN 61000 4 9 Enclosure 300 A m Radiated RF immunity EN 61000 4 3 Enclosure 20 V m 80 2700 MHz 10 V m 2700 6000 MHz 1 kHz sine 80 A...

Страница 23: ...hours Vibration IEC 60068 2 6 sine Operating 3 13 2 Hz 1mm 13 2 100 Hz 0 7 g 5 5 30 Hz 1 5 g 30 50 Hz 0 42 mm 50 500 Hz 4 2 g IEC 60068 2 64 random Operating 5 20 Hz 2 m s 20 2000 Hz 3 dB oct Shock IE...

Страница 24: ...cable to your computer USB port if drivers are needed they can be downloaded from our Web page 3 Use a terminal emulator and connect with correct speed and format 115200 8N1 to the assigned port For...

Страница 25: ...arm relay status contact Iin 80 mA max No 3 Digital in Input Digital in Uin 60 VDC max No 4 Digital in Input Digital in Iin 2 mA max The Status output is a potential free opto isolated normally closed...

Страница 26: ...D No voltage present on DC2 FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT Error BLINK Product configured as FRNT Focal Point RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Product elected as RSTP STP...

Страница 27: ...ooling This product uses convection cooling To avoid obstructing the airflow around the product use the following spacing rules Minimum spacing 25 mm 1 0 inch above below and 10 mm 0 4 inches left rig...

Страница 28: ...ne Management Tool in the WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administr...

Страница 29: ...u now have the choice to go ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplugging th...

Страница 30: ...30 6643 22701 Dimensions Measurements are stated in millimeters 92 1 Min 4mm Max 7 5mm 34 1 96 1 52 1 100 1...

Страница 31: ...REV H 6643 22701 2020 12 Westermo Network Technologies AB Sweden Westermo SE 635 35 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com...

Отзывы: