25
6643-22701
Power connection
1
2
3
4
4-position
Product
marking
Direction
Description
Input values
No. 1
+DC1
Input
Supply voltage input DC1
U
in
= (19 - 60) VDC
I
in
= 380 mA @ 24 VDC
P
In
= 9.1 W @ 24 VDC
No. 2
+DC2
Input
Supply voltage input DC2
No. 3
-COM
Input
Common
No. 4
-COM
Input
Common
Lynx supports redundant power connection. The positive inputs are +DC1 and +DC2, the negative input for
both supplies are -COM. Connect the primary voltage (e.g. +24 VDC) to the +DC1 pin and return to one of the
-COM pins on the power input.
I/O connection
1
2
3
4
4-position
Product
marking
Direction
Description
Input / Output values
No. 1
Output
Alarm relay (status) contact U
in
= 60 VDC max
No. 2
Status -
Output
Alarm relay (status) contact I
in
= 80 mA max
No. 3
Digital in +
Input
Digital in +
U
in
= 60 VDC max
No. 4
Digital in -
Input
Digital in -
I
in
= 2 mA max
The Status output is a potential free, opto-isolated normally closed solid-state relay.
This can be configured to monitor various alarm events within the Lynx product, see WeOS Management Guide.
An external load in series with an external voltage source is required for proper functionality.
For voltage/current ratings, see Interface Specification section.
The Digital in is an opto-isolated
digital input which can be used to
monitor external events. For volt-
age/current ratings, see Interface
Specification section:
Lynx
External
Load
Status
V
V
Digital In
+
1
2
3
4
-
Connector Information
Console port
Position Direction* / description Input/output values
No.1 In / out / GND
U = 3.3 VDC max
I = 24 mA max
No. 2 Out / Tx
No. 3 In / Rx
* Direction relative to this product.