Getting started

DDW-100 is easy to use and install, the units work in pair, one as have to be configured
as CO (

C

entral 

O

ffice) and one as CPE (

C

ustomer 

P

remises 

E

quipment).This configura-

tion is made by DIP-switches placed under the lid in DDW-100.

Connect the SHDSL Line

There is two options for connecting the SHDSL line:

1) Connect the twisted pair to DSL screw terminal 1 and 2 (polarity independent)

placed in the bottom of DDW-100.

2) Connect the line through RJ-11 to the DSL line placed in the front of DDW-100.

Note!

These two connections are parallel, it is not possible to use both at the same
time.

Connect the Ethernet Line

Connect Ethernet to the TX port placed in the front of DDW-100.
Factory settings for DDW-100 is plug and play mode where TX port is enabled for:

… Ethernet Auto-negotiation  enabled.
… Auto MDI/MDI-X.
… Auto-polarity enabled.

DDW-100 will automatically sense the speed of the connected unit and if a crossed cable
is used.

Settings in the units

The units operates in pairs, one is working as CO (

C

entral 

O

ffice) and one as CPE

(

C

ustomer 

P

remises 

E

quipment). Factory setting in DDW-100 is as CO.

Note!

Before connection and installation one of the connected unit have to be 
reconfigured as CPE

Depending on the quality of the line and the distance there is possibility to select the
optimised speed.

This is done via DIP switches in the unit configured as CO. Factory default is 192 kbit/s.
When selecting higher speed note if the DSL link is established, if not, the selected speed
is to high fore the distance.

Содержание DDW-100

Страница 1: ...Industrial Ethernet SHDSL Extender www westermo com Westermo Teleindustri AB 2005 User Guide 6621 2201 DDW 100 Preliminary...

Страница 2: ...it uses convection cooling To avoid obstructing the airflow around the unit follow the spacing recommendations see Installation section Care recommendations Follow the care recommendations below to ma...

Страница 3: ...residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio...

Страница 4: ...4 6601 2201 Declaration of Conformity...

Страница 5: ...6 15 03 Signal ports 250 V 50 Hz line to earth Voltage dips EN 61000 4 29 DC power ports 10 100 ms interruption and interruption 10 ms 30 reduction 10 ms 60 reduction 20 above 20 below rated voltage R...

Страница 6: ...the possibility to re use existing twisted copper pair with data rates from 192 Kbit s to 2 3 Mbit s in both directions Symmetric DSL according to standard ITU T G 991 2 Based on the quality of the l...

Страница 7: ...port placed in the front of DDW 100 Factory settings for DDW 100 is plug and play mode where TX port is enabled for Ethernet Auto negotiation enabled Auto MDI MDI X Auto polarity enabled DDW 100 will...

Страница 8: ...Electrical specification ITU T G 991 2 Annex B Data rate 192 kbit s to 2 312 Mbit s Protocol ITU T G 991 2 Annex E Clear Channel Data Circuit type TNV 1 Transmission range According to ITU T G 991 2 d...

Страница 9: ...ic port intended for support purpose Electrical specification IEEE std 802 3 2000 Edition Data rate 10 Mbit s 100 Mbit s manual or auto Duplex Full or half manual or auto Circuit type SELV Transmissio...

Страница 10: ...Spacing is recommended for the use of unit in full operating temperature range and service life Removal Press down the black support at the top of the unit See figure Mounting This unit should be moun...

Страница 11: ...t Transmitted Received data No 3 RD In Out Transmitted Received data No 4 No 5 No 6 RD In Out Transmitted Received data No 7 No 8 Shield HF connected DSL RJ 11 connector Position Direction Description...

Страница 12: ...ment Flash 1 only in CO Both CO and CPE have power and the line is connected Flash 2 both in CO and CPE Synchronisation phase of DSL link Flash 3 both in CO and CPE Activation phase of DSL link ON bot...

Страница 13: ...ethod S1 ON 1 2 3 4 5 6 7 8 Ethernet Auto negotiation enabled Auto MDI MDI X 10 Mbit s auto polarity enabled Auto negotiaion enabled CO Normal Mode ON 1 2 3 4 5 6 7 8 Speed 100 Mbit s ON 1 2 3 4 5 6 7...

Страница 14: ...HY Memory Power Isolation Isolation Isolation Screw Connector Screw Connector SHDSL modem RJ 11 Connector RJ 45 Connector Ethernet Interface LED Power SHDSL Link Application Block diagram Diagnostic p...

Страница 15: ...15 6601 2201 DDW 100 as an transparent Ethernet extender Network Network...

Страница 16: ...489 Oslo Norway Phone 47 220 903 03 Fax 47 220 903 10 E mail contact ontimenet com Westermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489...

Отзывы: