background image

Electromagnetic Compatibility

Phenomena

Test

Description

Level

ESD *

EN 61000-4-2

Enclosure contact 

± 6 kV

Enclosure air

± 8 kV

RF field AM modulated *  IEC 61000-4-3

Enclosure

10 V/m 80% AM (1 kHz), 80 – 1 000 MHz
20 V/m 80% AM (1 kHz), 80 – 2 000 MHz  

RF field 900 MHz *

ENV 50204

Enclosure

20 V/m pulse modulated 200 Hz, 900 ± 5 MHz

Fast transient *

EN 61000-4-4

Signal ports

± 2 kV

Power ports

± 2 kV

Surge *

EN 61000-4-5

Signal ports unbalanced ± 2 kV line to earth, ± 2 kV line to line 

Signal ports balanced

± 2 kV line to earth, ± 1 kV line to line

Power ports

± 2 kV line to earth, ± 2 kV line to line

RF conducted *

EN 61000-4-6

Signal ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Power ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Power frequency  

EN 61000-4-8

Enclosure

100 A/m, 50 Hz, 16.7 Hz & 0 Hz

magnetic field *

Pulse magnetic field *

EN 61000-4-9

Enclosure

300 A/m, 6.4 / 16 μs pulse

Voltage dips and 

EN 61000-4-11 AC power ports

10 & 5 000 ms, interruption

interruption *

10 & 500 ms, 30% reduction
100 & 1 000 ms, 60% reduction

Mains freq. 50 Hz *

EN 61000-4-16 Signal ports

100 V 50 Hz line to earth

Mains freq. 50 Hz

SS 436 15 03

Signal ports

250 V 50 Hz line to earth

Voltage dips 

EN 61000-4-29 DC power ports

10 & 100 ms, interruption

and interruption *

10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage

Radiated emission *

EN 55022

Enclosure

Class B

FCC part 15

Class B

Conducted emission *

EN 55022

AC power ports

Class B

FCC part 15

AC power ports

Class B

EN 55022

DC power ports

Class B

Dielectric strength *

EN 60950

Signal port to other

2 kVrms 50 Hz 1min

isolated ports

Power port to other

3 kVrms 50 Hz 1min

isolated ports

2 kVrms 50 Hz 1min (@ rated power < 60V)

Environmental

Temperature

Operating

–25 to +70°C

Storage & Transport

–25 to +70°C

Humidity

Operating

5 to 95% relative humidity

Storage & Transport

5 to 95% relative humidity

Altitude

Operating

2 000 m / 70 kPa

Service life

Operating

10 year

Vibration *

IEC 60068-2-6

Operating

7.5 mm, 5 – 8 Hz 
2 g, 8 – 500 Hz

Shock *

IEC 60068-2-27 Operating

15 g, 11 ms

Packaging

Enclosure

UL 94

PC / ABS

Flammability class V-1

Dimension W x H x D

35 x 121 x 119 mm

Weight

TBD kg

Degree of protection

IEC 529

Enclosure

IP 21

Cooling

Convection

Mounting

Horizontal on 35 mm DIN-rail

5

6601-2201

Type tests and environmental conditions

* Approvals according to Westermo standard, in the Beta-release approvals may not be completed

Содержание DDW-100

Страница 1: ...Industrial Ethernet SHDSL Extender www westermo com Westermo Teleindustri AB 2005 User Guide 6621 2201 DDW 100 Preliminary...

Страница 2: ...it uses convection cooling To avoid obstructing the airflow around the unit follow the spacing recommendations see Installation section Care recommendations Follow the care recommendations below to ma...

Страница 3: ...residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio...

Страница 4: ...4 6601 2201 Declaration of Conformity...

Страница 5: ...6 15 03 Signal ports 250 V 50 Hz line to earth Voltage dips EN 61000 4 29 DC power ports 10 100 ms interruption and interruption 10 ms 30 reduction 10 ms 60 reduction 20 above 20 below rated voltage R...

Страница 6: ...the possibility to re use existing twisted copper pair with data rates from 192 Kbit s to 2 3 Mbit s in both directions Symmetric DSL according to standard ITU T G 991 2 Based on the quality of the l...

Страница 7: ...port placed in the front of DDW 100 Factory settings for DDW 100 is plug and play mode where TX port is enabled for Ethernet Auto negotiation enabled Auto MDI MDI X Auto polarity enabled DDW 100 will...

Страница 8: ...Electrical specification ITU T G 991 2 Annex B Data rate 192 kbit s to 2 312 Mbit s Protocol ITU T G 991 2 Annex E Clear Channel Data Circuit type TNV 1 Transmission range According to ITU T G 991 2 d...

Страница 9: ...ic port intended for support purpose Electrical specification IEEE std 802 3 2000 Edition Data rate 10 Mbit s 100 Mbit s manual or auto Duplex Full or half manual or auto Circuit type SELV Transmissio...

Страница 10: ...Spacing is recommended for the use of unit in full operating temperature range and service life Removal Press down the black support at the top of the unit See figure Mounting This unit should be moun...

Страница 11: ...t Transmitted Received data No 3 RD In Out Transmitted Received data No 4 No 5 No 6 RD In Out Transmitted Received data No 7 No 8 Shield HF connected DSL RJ 11 connector Position Direction Description...

Страница 12: ...ment Flash 1 only in CO Both CO and CPE have power and the line is connected Flash 2 both in CO and CPE Synchronisation phase of DSL link Flash 3 both in CO and CPE Activation phase of DSL link ON bot...

Страница 13: ...ethod S1 ON 1 2 3 4 5 6 7 8 Ethernet Auto negotiation enabled Auto MDI MDI X 10 Mbit s auto polarity enabled Auto negotiaion enabled CO Normal Mode ON 1 2 3 4 5 6 7 8 Speed 100 Mbit s ON 1 2 3 4 5 6 7...

Страница 14: ...HY Memory Power Isolation Isolation Isolation Screw Connector Screw Connector SHDSL modem RJ 11 Connector RJ 45 Connector Ethernet Interface LED Power SHDSL Link Application Block diagram Diagnostic p...

Страница 15: ...15 6601 2201 DDW 100 as an transparent Ethernet extender Network Network...

Страница 16: ...489 Oslo Norway Phone 47 220 903 03 Fax 47 220 903 10 E mail contact ontimenet com Westermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489...

Отзывы: