6601-2201

Agency approvals and standards compliance

Type

Approval / Compliance

EMC

EN 61000-6-2, Immunity industrial environments*
EN 55024, Immunity IT equipment*
EN 61000-6-3, Emission residential environments*
FCC part 15 Class B*
EN 50121-4, Railway signalling and telecommunications apparatus*
IEC 62236-4, Railway signalling and telecommunications apparatus*

Safety

EN 60950-1, IT equipment
UL listed, UL 60950-1*
CSA 22.2 No 60950-1-03*

SHDSL

ITU-T G.991.2, G.SHDSL standard*

FCC Part 15.105 Notice:

This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the 
FCC Rules.These limits are designed to provide reasonable pro-
tection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communica-
tions. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of
the following measures:

… Reorient or relocate the receiving antenna
… Increase the separation between the equipment and receiver
… Connect the equipment into an outlet on a circuit different

from that to which the receiver is connected

… Consult the dealer or an experienced radio/TV technician 

for help.

* Approvals according to Westermo standard, in the Beta-release approvals may not be completed.

Содержание DDW-100

Страница 1: ...Industrial Ethernet SHDSL Extender www westermo com Westermo Teleindustri AB 2005 User Guide 6621 2201 DDW 100 Preliminary...

Страница 2: ...it uses convection cooling To avoid obstructing the airflow around the unit follow the spacing recommendations see Installation section Care recommendations Follow the care recommendations below to ma...

Страница 3: ...residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio...

Страница 4: ...4 6601 2201 Declaration of Conformity...

Страница 5: ...6 15 03 Signal ports 250 V 50 Hz line to earth Voltage dips EN 61000 4 29 DC power ports 10 100 ms interruption and interruption 10 ms 30 reduction 10 ms 60 reduction 20 above 20 below rated voltage R...

Страница 6: ...the possibility to re use existing twisted copper pair with data rates from 192 Kbit s to 2 3 Mbit s in both directions Symmetric DSL according to standard ITU T G 991 2 Based on the quality of the l...

Страница 7: ...port placed in the front of DDW 100 Factory settings for DDW 100 is plug and play mode where TX port is enabled for Ethernet Auto negotiation enabled Auto MDI MDI X Auto polarity enabled DDW 100 will...

Страница 8: ...Electrical specification ITU T G 991 2 Annex B Data rate 192 kbit s to 2 312 Mbit s Protocol ITU T G 991 2 Annex E Clear Channel Data Circuit type TNV 1 Transmission range According to ITU T G 991 2 d...

Страница 9: ...ic port intended for support purpose Electrical specification IEEE std 802 3 2000 Edition Data rate 10 Mbit s 100 Mbit s manual or auto Duplex Full or half manual or auto Circuit type SELV Transmissio...

Страница 10: ...Spacing is recommended for the use of unit in full operating temperature range and service life Removal Press down the black support at the top of the unit See figure Mounting This unit should be moun...

Страница 11: ...t Transmitted Received data No 3 RD In Out Transmitted Received data No 4 No 5 No 6 RD In Out Transmitted Received data No 7 No 8 Shield HF connected DSL RJ 11 connector Position Direction Description...

Страница 12: ...ment Flash 1 only in CO Both CO and CPE have power and the line is connected Flash 2 both in CO and CPE Synchronisation phase of DSL link Flash 3 both in CO and CPE Activation phase of DSL link ON bot...

Страница 13: ...ethod S1 ON 1 2 3 4 5 6 7 8 Ethernet Auto negotiation enabled Auto MDI MDI X 10 Mbit s auto polarity enabled Auto negotiaion enabled CO Normal Mode ON 1 2 3 4 5 6 7 8 Speed 100 Mbit s ON 1 2 3 4 5 6 7...

Страница 14: ...HY Memory Power Isolation Isolation Isolation Screw Connector Screw Connector SHDSL modem RJ 11 Connector RJ 45 Connector Ethernet Interface LED Power SHDSL Link Application Block diagram Diagnostic p...

Страница 15: ...15 6601 2201 DDW 100 as an transparent Ethernet extender Network Network...

Страница 16: ...489 Oslo Norway Phone 47 220 903 03 Fax 47 220 903 10 E mail contact ontimenet com Westermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489...

Отзывы: