58
925.224.3 - EN
INSTRUCTIONS PERTAINING TO THE INSTALLER
3-WAY VALVE MOTOR ELECTRICAL CONNECTION (Models 1.310 Fi - 1.240 Fi)
The 3-way valve motor and relevant wiring are supplied separately as a kit.
Connect the 3-way valve motor as shown in figure 19.1.
To connect the wiring, proceed as follows:
1) undo the 3 fixing screws and lift the control panel;
2) connect the 3-way valve motor wires (white-red-black) as shown in figure 19;
IMPORTANT:
check correct clamping of the wires on the connector CN1.
3) secure the wiring cable to the control panel cable clamp;
4) close the control panel, securing it with the fixing screws.
0512_1204
FAN
THREE-WAY VALVE
MOTOR
PUMP
WHITE
RED
BLACK
M
C
M
C
CN1
3-WAY VALVE MOTOR ASSEMBLY
(Models 1.310 Fi - 1.240 Fi)
0512_2005
Note:
before installing the 3-way motor remove the cap
upon the 3 way valve.
Figure 19
Figure 19.1
27. ELECTRICAL CONNECTION TO REMOTE CONTROL DEVICE
Note: for model 1.310 Fi, connect the remote control device as described in paragraph 28.1 (figure 20).
(SUPPLIED AS AN ACCESSORY)
The remote control device is not a
standard boiler component as it is su pplied as
an accessory. Open the elec- tronic board and
connect the cable (supplied together with the
two-pin ter- minal board) to connector CN7 on the
electronic boiler board. Connect the ter- minals of
the remote control device to the two-pin terminal
board (figure 19).
Figure 20
0610_1302 / CG_1856
CN 7