Figure 6-5: Control Mode Page, continued
Item #
Section
8
Isolation
Isolation Value
When power is on, an isolation check is
performed and the values display.
Isolation
Measured isolation value (air interface
attenuation value) between donor antenna
and service antenna. The isolation check can
be performed with the RF on or off.
On = Measure the Isolation and display the
value in the Isolation Value field
Off = Do not measure the isolation
Isolation Recheck
The isolation check can be performed with the
RF on or off.
Isolation Attenuation This allows control of the isolation
attenuation. After isolation check, attenuation
is set automatically (0 to 30).
Note: Neither the isolation check nor recheck will indicate a change in
power levels if the unit’s own power has been switched off.
9
VSWR
DL/UL
Ratio
VSWR Ratio Status Display, 0 to 30.
Limit
VSWR Ratio Alarm Limit, Set 0 to 30.
On/Off
VSWR Alarm Display Enable (On)/Display (Off).
10
Location
Company
Company information display
Address
Address information display
City
City information display
State
State information display
Contact
Contact information display