3.5
GUI Items
Table 3-5: GUI Items
Refer to Section 6 System Operation for more information about the GUI.
Parameters
Specifications
Notes
UL/DL Output Readings
5dBm to 30dBm
Reads and displays the UL/DL
output power
Alarm Readout Displays
PLL LD(Lock Detector), Isolation,
UL/DL shutdown, DC Fail, Relay
Status, UL/DL VSWR, Manual
Amp
Displays alarm status
UL/DL Shutdown Setting
23dBm to 30dBm
Use to set the peak power
(shutdown level)
UL/DL Gain Setting
0dB to 30dB
Used to set the UL/DL system
gain.
System Location Display
PS51080 PS-SMR700/800
Company, Address, City, State,
Contact
Displays the repeater name and
information.
Control Send
All Control Page Settings
Used to save settings in the
Control page.
Isolation
Settable to 0db -or- 15dB.
VSWR
Adjustable from 1-30
Quit
None
Closes the GUI page.